ATC-100 CONTROLLER

< Back

Financing & Insurance
See our Offers
View Product Downloads
Please answer to continue. Select an option to continue. Enter a valid email address.
Yes, I would like to receive future communications from Caterpillar extended enterprise and dealer network

Overview

The ATC-100 is a comprehensive and multifunctional microprocessor-based ATS controller. It is a compact and self-contained panel-mounted device that is designed to replace traditional relay and solid-state logic panels.The ATC provides both fixed and jumper-selectable settings to allow for a range of applications. It operates from all system voltages between 120 and 480 Vac, single-phase and three phase at 50 or 60 Hz. The ATC-100 monitors the condition of the three-phase line to line voltage and the frequency of both the utility and generator power sources. It can also be set up for single-phase operation. The ATC-100 provides the necessary intelligence to ensure that the transfer switch operates properly through a series of selectable sensing and timing functions.

Technical Summary

Units:
Rating Range 120 to 480V, single phase and three phase @ 50/60 Hz 120 to 480V, single phase and three phase @ 50/60 Hz Less
Transfer Type Switch application dependent Switch application dependent Less
Switch Type Switch application dependent Switch application dependent Less

ATC Controller Specifications

Input control voltage 95 to 145 Vac 50/60 Hz 95 to 145 Vac 50/60 Hz Less
Voltage measurements of Utility VAB generator VAB
VBC generator VBC
VCA generator VCA
VAB generator VAB
VBC generator VBC
VCA generator VCA
Less
Voltage measurement range 0 to 575 Vac rms (50/60 Hz) 0 to 575 Vac rms (50/60 Hz) Less
Voltage measurement accuracy ± 1% of full scale ± 1% of full scale Less
Frequency measurements of Generator Generator Less
Frequency measurement range 40 Hz to 70 Hz 40 Hz to 70 Hz Less
Frequency measurement accuracy ±0.3 Hz over the measurement range ±0.3 Hz over the measurement range Less
Undervoltage dropout 80% of the nominal system voltage 80% of the nominal system voltage Less
Undervoltage pickup 90% of the nominal system voltage 90% of the nominal system voltage Less
Underfrequency dropout range 90% of the nominal system frequency 90% of the nominal system frequency Less
Underfrequency pickup range 95% of the nominal system frequency 95% of the nominal system frequency Less
Overfrequency dropout range 115% of the nominal system frequency 115% of the nominal system frequency Less
Overfrequency pickup range 110% of the nominal system frequency 110% of the nominal system frequency Less
Operating temperature range –20 to +70°C (–4 to +158°F) –20 to +70°C (–4 to +158°F) Less
Storage temperature range –30 to +85°C (–22 to +185°F) –30 to +85°C (–22 to +185°F) Less
Operating humidity 0 to 95% relative humidity (noncondensing) 0 to 95% relative humidity (noncondensing) Less
Operating environment Resistant to ammonia, methane, nitrogen, hydrogen and hydrocarbons Resistant to ammonia, methane, nitrogen, hydrogen and hydrocarbons Less
Generator start relay 5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load 5A, 1/6 hp @ 250 Vac Vac 5A @ 30 Vdc with a 150W maximum load Less
K1, K2 relays
10A, 1–3 hp @ 250 Vac

10A@30 Vdc

10A, 1–3 hp @ 250 Vac

10A@30 Vdc
Less
Applicable testing UL-recognized component
UL 1008, UL 991 Environmental IEC 61000-4-2, 61000-4-3, 61000-4-4,
UL-recognized component
UL 1008, UL 991 Environmental IEC 61000-4-2, 61000-4-3, 61000-4-4,
Less
Applicable testing continued 61000-4-5, 61000-4-6, 61000-4-11
CISPR 11, Class B
FCC Part 15, Class B
CSS 22.2-178
61000-4-5, 61000-4-6, 61000-4-11
CISPR 11, Class B
FCC Part 15, Class B
CSS 22.2-178
Less
Enclosure compatibility NEMA 1, NEMA 3R and NEMA 12
UV-resistant ATC-100 faceplate
NEMA 1, NEMA 3R and NEMA 12
UV-resistant ATC-100 faceplate
Less

Performance Features

  • Source 1 sensing:
    • Undervoltage / underfrequency
    • Overfrequency

  • Source 2 sensing:
    • Undervoltage / Overfrequency

  • Controller settings via jumpers located at the rear of the unit
  • Mimic diagram with source available and connected LED indication
  • System test pushbutton
  • Plant Exerciser - Selectable day, off, 7, 14 or 28 day intervals with fixed 15 minute run time
  • Monitor utility and generator power source voltages and generator power source frequency
  • Provides undervoltage protection of the utility and generator power sources
  • Provides underfrequency and overfrequency protection of the generator power source
  • Permits easy customer setup
  • Permits system testing