Financing & Insurance
See our Offers
View Product Downloads
Please answer to continue. Enter a valid email address.

Overview

Cat® C4.4 Diesel Marine Generator Set has three phase ratings of 50 Hertz at 38.0, 51.5, and 69.0 ekW with heat exchanger cooling and at 36.0, 49.0, and 65.0 ekW with radiator cooling that meet EU CCNR2 emissions standards. The C4.4 also has three phase ratings of 60 Hertz at 44.0, 58.5, 76.0, and 99.0 ekW with heat exchanger cooling and of 42.0, 56.0, 72.0, and 95.0 ekW with radiator cooling that meet U.S. EPA Tier 2 commercial emissions standards.

Generator Set Specifications

Units:
Minimum Rating 36.0R ekW (45 kVA) 36.0R ekW (45 kVA) Less
Maximum Rating 99.0 ekW (123 kVA) 99.0 ekW (123 kVA) Less
Frequency 50 Hz or 60 Hz 50 Hz or 60 Hz Less
Speed 1500 rpm or 1800 rpm 1500 rpm or 1800 rpm Less

Engine Specifications

Engine Model In-line 4, 4-Stroke-Cycle Diesel In-line 4, 4-Stroke-Cycle Diesel Less
Bore 4.13 in 105.0 mm Less
Displacement 269.0 in3 4.4 L Less
Stroke 5.0 in 127.0 mm Less
Aspiration NA, T, TA NA, T, TA Less
Governor Type Electronic Electronic Less

Generator Set Configurations

Emissions/Fuel Strategy EPA Tier 2 (60 Hz), EU 97/68EC Stage II (50 Hz) EPA Tier 2 (60 Hz), EU 97/68EC Stage II (50 Hz) Less

Generator Set Dimensions

Length 68.9 in 1750.0 mm Less
Width 47.8 in 1215.0 mm Less
Height 39.4 in 1000.0 mm Less
Weight 805 kg (1775 lb) - 1015 kg (2338 lb) 805 kg (1775 lb) - 1015 kg (2338 lb) Less

Generator Specifications

Excitation Separately excited from auxiliary winding to provide 300% short circuit current up to 10 seconds Separately excited from auxiliary winding to provide 300% short circuit current up to 10 seconds Less
Pitch 2/3 2/3 Less
Number of leads 12 lead reconnectable 12 lead reconnectable Less
Insulation Class H Class H Less
IP Rating IP23 water protection (IP44 available for certain models, contact your dealer for information) IP23 water protection (IP44 available for certain models, contact your dealer for information) Less
Voltage regulator Solid state voltage regulator with integral voltage adjustment potentiometer Solid state voltage regulator with integral voltage adjustment potentiometer Less

Economical

Low owning and operating costs with competitive pricing, longlife construction, and extended service intervals

Easy to install

Plug and play remote instrument panels

Environmentally responsible

Low emission, noise, and vibration levels; 60 Hz meets EPA Tier 2, 50 Hz meets EU 97/68EC Stage II regulations

Safe

Automatic shutdowns for overspeed, high fresh water temperature, low engine oil pressure, and high exhaust temperature (when fitted with a wet exhaust system).

Flexible

Available as an open set or with sound attenuated enclosure, and with radiator-, heat exchanger-, or keel-cooled options

Excellent power quality

Suitable for sophisticated on-board equipment (computers, etc.)

Single source of supply for propulsion and generator sets

Reduced service costs and port time

C4.4 Standard Equipment

Air Inlet System
  • Air cleaner, single element canister type w/ service indicator and rain cap
  • Dry insulated turbocharger (DIT and DITA models only)
  • Glowplug cold start system

Cooling System
  • Heat exchanger cooled packages w/ Cupro-nickel tube bundle (sized for 50 o C ambient air and 32 o C sea water) or Keel cooled packages (sized for 50 o C ambient air)
  • De-aeration expansion tank
  • Plate-type engine oil cooler
  • Gear driven centrifugal jacket water pump
  • Gear driven self priming sea water pump
  • Caterpillar Extended Life Coolant (heat exchanger cooled packages)

Exhaust System
  • Dry insulated turbocharger
  • Water-cooled exhaust manifolds

Fuel System
  • Primary fuel filter / water separator w/ NPT and BSP connectors (ship loose)
  • Secondary fuel filter (LH)
  • Fuel priming pump electric
  • Energize to run shutoff solenoid

Generator
  • 12 lead reconnectable
  • 3 phase all models
  • Brushless
  • Separately excited from auxiliary winding to provide 300% short circuit current up to 10 seconds
  • 2/3 pitch
  • Broad voltage band
  • IP23 water protection
  • Solid state voltage regulator w/ integral voltage adjustment potentiometer
  • Class H insulation
  • Connection poles

Governing System
  • Electronic governor

Lube System
  • Lubricating oil
  • Oil filter (LH)
  • Dipstick (LH)
  • Fumes disposal (closed system)

Mounting System
  • Steel base frame with drip pan
  • Anti-vibration mounts

Starting/Charging System
  • Negative isolated ground electric system

General
  • Single side service (LH)
  • Keel cooled gensets do not include the keel cooler(s)

C4.4 Optional Equipment

On-board spars and tool kit

AC circuit breaker

Siphon break

Instrumentation

Duplex secondary fuel filter

Governor droop kit (enables paralleling with appropriate customer supplied switchgear)

Remote expansion tank kit

Double wall fuel lines and mounted alarm reservoir

Flexible fuel lines

Primary fuel filter with water separator

Space heater kit
  • 240V AC, 120V AC

Remote start/stop panels

Air starter

Jacket water heater

Cat® Dealer Service

Buy any piece of Cat® equipment and also get the full support and commitment of your local Cat Dealer.

Contact your local dealer
Financing & Insurance

You can count on Cat Financial to provide the best financial solutions, built just for you.

See our Offers