< Back

View Product Downloads
Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

Overview

Caterpillar electric power stands for reliable energy supply. Especially during the energy system transformation, Cat generator sets close the energy gap caused by renewable energy source such as wind and photo voltaic. Short ramp up time, low operating costs and rapid maintenance times ensures a high availability according to the need of our customers. Combined heat /cool and power solutions allow our customers to maximize the efficiency and earnings paired with low emissions. Wherever power is needed around the globe, Caterpillar is able to support you with the best products and services to maximize your profit.

Generator Set Configurations

Units:
Specific Energy Consumption Up To 6893.0 7272.0 Less
Specific Pilot Fuel Consumption (Only Dual Fuel) Up To 70.0 74.0 Less

Generator Set Specifications

Genset Rating Range 10580 - 14110 kWe 10580 - 14110 kWe Less
Fuel Type Gas / diesel oil / heavy fuel oil (HFO) / crude oil Gas / diesel oil / heavy fuel oil (HFO) / crude oil Less
Emission Level Up To World bank emission certification (Stage 2) World bank emission certification (Stage 2) Less
Engine Type 4-stroke-engine 4-stroke-engine Less
Voltage 3-13.8 kV 3-13.8 kV Less
Configuration 12.16 cylinder 12.16 cylinder Less
Mean Effective Pressure Up To 309.0 psi 21.3 bar Less
Bore 18.11 in 460.0 mm Less
Frequency At Speed 50 Hz @ 500 / 60 Hz @ 514 50 Hz @ 500 / 60 Hz @ 514 Less
Normal Ramp Up To 100% Load 80 s 80 s Less
Emergency Ramp Up 10% To 100% Load 25 s 25 s Less
Swept Volume 6186.0 in³ 101.4 l/cyl Less
Stroke 24.02 in 610.0 mm Less
Aspiration Turbocharged-aftercooled Turbocharged-aftercooled Less
Engine Efficiency Up To 48.50% 48.50% Less
Specific Lube Oil Consumption 0.001 0.6 Less
Ready To Accept Loads (Preheated/Vented) 40 s 40 s Less
Specific Fuel Oil Consumption (WB I) Up To 0.406 184.0 Less
Specific Fuel Oil Consumption (WB II) Up To 0.406 184.0 Less
Engine Rating Range 10800 - 14400 kW 10800 - 14400 kW Less
Height - Maximum 188.0 in 4773.0 mm Less
Height - Minimum 183.0 in 4659.0 mm Less
Length - Maximum 652.0 in 16565.0 mm Less
Length - Minimum 562.0 in 14280.0 mm Less
Width - Maximum 159.0 in 4027.0 mm Less
Width - Minimum 153.0 in 3890.0 mm Less
Dry Weight - Genset (maximum) 630521.0 lb 286.0 ton (US) Less
Dry Weight - Genset (minimum) 500449.0 lb 227.0 ton (US) Less

CM46DF V-Type Standard Equipment

Fuel System
  • Circulation module
  • Pre-pressure module
  • Separator module
  • Engine ventilation module (only dual fuel (DF) and gas)
  • Gas valve unit (GVU) (only dual fuel (DF) and gas)
  • Ignition fuel oil module (only dual fuel (DF))

Lubricating Oil System
  • Combined module: cooling water system and lube oil system
  • Lube oil separator module
  • Piping interface module

Cooling Water System
  • Combined module: see lube oil system
  • Cooling water system with radiators
  • Piping interface module

Starting System
  • Starting air compressor module
  • Starting air receiver module

Combustion Air System
  • Air filter - pocket
  • Air filter - oil bath
  • Air filter - pulse

Exhaust System
  • Exhaust gas silencer
  • Selective catalytic reduction (SCR) system
  • Oxidation catalytic (Oxicat) converter system
  • Exhaust gas ventilation module (only dual fuel (DF) and gas)

Control & Monitoring System
  • Local control panel (LCP)
  • Local data panel (LDP) / generator control panel (GCP)
  • Motor control center module (MCC)
  • Engine monitoring package
  • Gas leak detection per cylinder (only dual fuel (DF) and gas)

Mounting System
  • Elastic mounting - genset/engine