Cat Switchgear

< Back

Caterpillar offers a range of integrated switchgear solutions, from standard floor standing low voltage ACB's breakers 1600A - 4000A to custom solutions, which can include multiple utility sources with multiple generator paralleling applications where complex control philosophies are employed. Caterpillar has developed a modular low voltage switchgear enclosure range which integrates controls and PLC solutions. Built around 150mm modules in 3 axis, internally the framework utilises a 25 mm grid allowing a fully configurable system. Enclosure options include form 4 separation, IP54 protection and 50 °C capabilities.
Financing & Insurance
See our Offers

Overview

Caterpillar offers a range of integrated switchgear solutions, from standard floor standing low voltage ACB's breakers 1600A - 4000A to custom solutions, which can include multiple utility sources with multiple generator paralleling applications where complex control philosophies are employed.

Enclosure Rating

Units:
Configuration IP4X IP4X Less

Operating Temperature

Operating Temperature 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) 35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F) Less

Dimensions

Standard Widths 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. 600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A. Less
Standard Depths 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers 300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers Less
Standard Heights Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping Less

Application

Application LV 380…480 VAC, 50 Hz, 3-Phase. LV 380…480 VAC, 50 Hz, 3-Phase. Less

Modes of Operation

Modes of Operation Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc. Less

Technical Summary

Technical Summary Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers. Less

Cat Switchgear