3516B (50 Hz) with Upgradeable Package

< Back

View Product Downloads
Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

3516B (50 Hz) with Upgradeable Package Standard Equipment

Air Inlet System
  • Air Cleaner; single element canister type

Control Panels
  • Auto / start / stop control
  • Engine cool-down timer
  • Environmental sealed front face
  • Emergency stop pushbutton
  • Text alarm / event descriptions
  • 24 Volt DC operation
  • Controls:
  • Generator mounted - Rear facing
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter.
  • Limiter and exciter diode monitor
  • Generator set packages include Caterpillar' s Voltage Regulator.
  • EMCP 4.2B
  • Speed adjust
  • Alarm acknowledge
  • Engine cycle crank
  • Load histogram feature
  • Lamp test
  • Digital indication for:
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • RPM
  • PLC functionality
  • Operating hours
  • Oil pressure (psi, kPa or bar)
  • Coolant temperature
  • DC volts
  • Power Factor (per phase & average)
  • Volts (L-L & L-N)
  • kW (per phase, average & percent)
  • Amps (per phase & average)
  • Frequency (Hz)
  • kVA (per phase, average & percent)
  • kVAr (per phase, average & percent
  • Low oil pressure - High coolant temperature
  • kVAr-hr (total)
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • kW-hr (total)
  • Overspeed
  • Low coolant temperature
  • Failure to start (overcrank)
  • Emergency stop
  • Over/Under voltage (27 / 59)
  • Generator phase sequence
  • Low coolant level
  • Programmable protective relaying functions:
  • 6 Customer programmable digital inputs
  • Over/Under Frequency (81 o/u)
  • Reverse Reactive Power (kVAr) (32RV)
  • Serial annunciator module data link
  • Reverse Power (kW) (32)
  • Number of I/O varies on options selected:
  • Overcurrent (50 / 51)
  • Cat Connect
  • 4 Programmable relay outputs (Form A)
  • Communications:
  • Customer data link (Modbus RTU)
  • 1 Programmable digital outputs
  • 1 Programmable relay outputs (Form C)
  • Accessory module data link
  • 3 Analog inputs

Cooling System
  • Certified standard PGS provided
  • ATAAC - 3516E Package Radiators shipped installed

Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Fuel priming pump
  • Flexible fuel lines - shipped loose

General
  • Right hand servicing
  • SAE Standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments
  • Busbar connections, right side extension box, bottom cable entry
  • High Voltage:
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • Form wound
  • Internal excitation
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • 3 Phase brushless, salient pole
  • Medium Voltage:
  • NEMA standard hole pattern
  • Permanent magnet
  • Permanent magnet
  • Winding temperature detectors
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
  • Winding temperature detectors
  • Low voltage:
  • Form wound
  • 6 Leads
     
  • Random wound
  • Anti Condensation Space Heater
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry
  • NEMA standard hole pattern

Governing System
  • ADEM A3

Literature
  • English

Lubrication System
  • Integral lube oil cool
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Gear type lube oil pump
  • Oil drain lines and valve
  • Fumes disposal

Mounting System
  • Rails - engine / generator / radiator mounting
  • Rubber anti-vibration mounts (shipped loose)
  • Anti-vibration mounts (shipped loose)

Starting System
  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery disconnect switch
  • Battery and battery rack w/cables

3516B (50 Hz) with Upgradeable Package Optional Equipment

Control System
  • EMCP 4.3, EMCP 4.4
  • Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Air Inlet System
  • Dual element air cleaner
  • Single element filter

Engine Options
  • Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Battery Charger: [ ] 10A [ ] 20A [ ] 35A
  • Starting Aids: [ ] 220V 50 Hz Jacket Water Heater
  • Muffler: [ ] Industrial Grade
  • Starting Motors: [ ] Standard [ ] Heavy Duty
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

Cooling System
  • Standard ambient radiators
  • Coolant
  • Optional installed radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Standard ambient ATAAC radiators

Crankcase System
  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Exhaust System
  • Y-Adapters
  • Flanges
  • Tier 4 clean emission MOD Kits
  • Clean emission parts
  • Flange and exhaust expanders
  • Flexible fittings
  • Exhaust offset
  • Mufflers
  • Tier 4 dosing cabinet
  • Tier 4 clean emissions module
  • Elbows

Alternators
  • Temperature Rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Power Termination
  • Power Termination: [ ] Bus Bar [ ] Circuit Breaker
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

Fuel System
  • Fuel Priming Pumps (Tier 4) - Manual or electric
  • Primary Fuel Filter

Extended Service Contract (ESC)
  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

General
  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Generators and Attachments
  • Generator conversion
  • Space heater
  • Alternator air cleaner
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostate for space heater
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

Instrumentation
  • Pyrometer and thermocouples

Lubrication System
  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System
  • Puck style low efficiency isolators
  • IBC vibration isolators
  • Spring type vibration isolators

Power Connections
  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Left side power connections
  • 2700 Frame, four lead, four terminal
  • Ground cables between generator and terminal box
  • Low voltage circuit breakers
  • Rear power connections

Special Tests / Reports
  • Torsional vibration analysis reports
  • Generator set fuel consumption test
  • PGS test report @ 1.0 power factor
  • Fuel consumption test
  • Standard engine test charge
  • IBC certification
  • OSHPD certification
  • Canadian Standards Association certification
  • PGS test report @ 0.8 power factor
  • generator test report

Starting and Charging
  • 10, 20, 35 and 50 amp battery chargers
  • Air starting motors
  • Air pressure regulator
  • Electric starting motors
  • Starter cover
  • Jacket water heaters
  • Engine barring device
  • 24 Volt battery set - Dry

Extended Service Coverage
  • Platinum, Gold and Silver coverage

Cat Generator Set Package

  • Cat generator set packages have been fully prototype tested
  • Accepts 100% block load in one step and meets NFPA 110 loading requirements
  • Conform to ISO 8528-5 steady state and transient response requirements

Cat Diesel Engine

  • Reliable, rugged, durable design
  • Field-proven in thousands of applications worldwide
  • Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight

SR5 Alternator

  • Superior motor starting capability minimizes need for oversizing alternator
  • Designed to match performance and output characteristics of Cat diesel engines
  • Robust Class H insulation

EMCP 4 Control Panel

  • User-friendly interface and navigation
  • Scalable system to meet a wide range of installation requirement
  • Expansion modules and site-specific programming for specific customer requirements

Cooling System

  • Designed to operate in standard ambient temperatures up to 50°C (122°F)
  • Contact your Cat Dealer for specific ambient and altitude capabilities

Certifications

  • IBC Seismic Certification
  • EEC Declaration of Conformity
  • Eurosian Conformity

One Safe Source

  • Components used in the generator set are selected at the design stage to provide optimum package performance
  • The generator set is fully assembled at a Caterpillar facility following our quality guidelines
  • Each generator set package is tested before leaving the Caterpillar facility
  • Cat product support, including dealer service, parts and warranty covers the entire Cat power system

World Wide Product Support

  • Cat dealers have over 1,800 dealer branch stores operating in 200 countries
  • Your local Cat dealer provides extensive post-sale support, including maintenance and repair agreements

Overview

Producing reliable power from 1750 kVA to 2250 kVA at 50 Hz, our 3516B diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 per cent rated load in one step. The generator set offers both low fuel consumption and low emission systems.

Generator Set Specifications

Units:
Minimum Rating 1750 kVA 1750 kVA Less
Maximum Rating 2250 kVA 2250 kVA Less
Emissions/Fuel Strategy Low fuel, Low Emissions Low fuel, Low Emissions Less
Voltage 380 to 11000 Volts 380 to 11000 Volts Less
Frequency 50 Hz 50 Hz Less
Speed 1500 rpm 1500 rpm Less
Duty Cycle Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous Less

Engine Specifications

Engine Model 3516B TA, V-16, 4-Stroke Water-Cooled Diesel 3516B TA, V-16, 4-Stroke Water-Cooled Diesel Less
Bore 6.69 in 170.0 mm Less
Stroke 7.48 in 190.0 mm Less
Displacement 4210.64 in 69.0 l Less
Compression Ratio 14.0:1 Std 14.0:1 Std Less
Aspiration TA TA Less
Fuel System Electronic unit injection Electronic unit injection Less
Governor Type Adem™3 Adem™3 Less

Generator Set Dimensions

Length - Maximum 234.5 in 5957.0 mm Less
Width - Maximum 90.0 in 2286.0 mm Less
Height - Maximum 98.2 in 2494.0 mm Less
Dry Weight - Genset (maximum) 34460.0 lb 15630.0 kg Less

Application Centre

Explore valuable resources for generator sizing, specification, and training materials. SpecSizer evaluates load types, collects data, and organises it to help you select the generator set that's best for you. Find product comparisons, technical data, product sizing, and more using our technical information portal (TIP) specifically created for consultants, architects, engineers, and owners.

visit page

Why Choose Cat® Electric Power?

Caterpillar offers a comprehensive variety of electric power systems, customised to fit your needs. Our specialised systems deliver high power and performance in industries across the globe. With Caterpillar, you get outstanding manufacturing quality, expert support, and the essential tools and applications to complete any project.

Learn More About Electric Power

EMCP 4 Generator Set Controls

Cat generator sets provide a complete factory-built solution with fully featured standard and advanced controls. Optional accessories enhance the capabilities of the genset package-mounted control system.

Learn More