Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

Overview

The C15 diesel generator sets have been developed for your mission critical, standby and prime applications. Producing reliable power from 365 to 550 kVA at 50 Hz, meeting ISO 8528-5 transient response requirements and built to accept 100 percent rated load in one step. The engines are certified Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 or Tier 3 Nonroad Equivalent Emission Standards), EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards Emissions / Fuel Strategy.

Generator Set Specifications

Units:
Minimum Rating 365 kVA 365 kVA Less
Maximum Rating 550 kVA 550 kVA Less
Emissions/Fuel Strategy Tier 2 or Tier 3 Tier 2 or Tier 3 Less
Voltage 208 to 600 Volts 208 to 600 Volts Less
Frequency 50 Hz 50 Hz Less
Speed 1500 rpm 1500 rpm Less
Duty Cycle Standby, Prime Standby, Prime Less

Engine Specifications

Engine Model C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel Less
Bore 5.4 in 137.2 mm Less
Stroke 6.75 in 171.4 mm Less
Displacement 927.56 in³ 15.2 l Less
Compression Ratio 16.1:1 16.1:1 Less
Aspiration Air to Air Aftercooled Air to Air Aftercooled Less
Fuel System MEUI MEUI Less
Governor Type Adem™A4 Adem™A4 Less

Generator Set Dimensions

Length - Maximum 150.8 in 3830.0 mm Less
Width - Maximum 58.3 in 1481.0 mm Less
Height - Maximum 86.3 in 2193.0 mm Less

Cat Generator Set Package

Cat Diesel Engine

SR5 Alternator

EMCP Control Panel

Cooling System

One Safe Source

World Wide Product Support

C15 (50 Hz) Standard Equipment

Air System
  • Turbocharger
  • Aftercooler core
  • Air Cleaner - Non Canister disposable paper filter

Air Inlet
  • Air Cleaner

Control Panel
  • EMCP 4.2

Cooling
  • Package mounted radiator

Cooling System
  • Caterpillar Extended Life Coolant
  • Radiator and cooling fan with guard
  • Fan drive, battery charging alternator drive
  • Coolant drain line with valve

Exhaust
  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied

Fuel
  • Primary fuel filter with integral water separator
  • Secondary fuel filter
  • Fuel priming pump

Fuel System
  • Engine fuel transfer pump
  • Primary fuel filter w/integral water separator & secondary filter
  • Fuel priming pump
  • Flexible fuel lines
  • Fuel cooler

Generator
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection
  • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

Power Termination
  • Bus Bar

Generator and Attachments
  • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
  • Optional LC frame generator - IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel
  • Integrated Voltage Regulator
  • Power center, IP22

Mounting
  • Rubber vibration isolators

Governing System
  • Cat Electronic Governor (ADEM A4).

Lube System
  • Oil cooler
  • Oil drain valves

Mounting System
  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines

Starting/Charging
  • 24 Volt battery with rack and cables

General
  • Engine and alternator pre paint, Caterpillar yellow

C15 (50 Hz) Optional Equipment

Air Inlet System
  • Single element air cleaner
  • Dual element air cleaner

Exhaust
  • Industrial, Residential, Critical Mufflers

Certifications
  • EU certificate of conformance
  • Global certification for CIS

Generator
  • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Oversize and premium generators
  • Anti-condensation heater

Power Termination
  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Circuit breakers
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) circuit breakers - Package mounted
  • Auxiliary contacts, circuit breaker
  • 3 Pole (IEC-100% rated) circuit breakers - Package mounted
  • 3 Pole (IEC-100% rated) circuit breakers - Motorised
  • Power terminal strip
  • 4 Pole (IEC-100% rated) circuit breakers - Motorised
  • Pad-lockable circuit breaker device

Generator and Attachments
  • Permanent magnet generator
  • LC frame CIP generator
  • Oversize LC frame generator
  • Space heaters
  • CIP a frame generator
  • Oversize A frame generator
  • Ingress protection
  • A frame generator - IP21 Protection
  • LC frame generator

Control Panels
  • Fuel level sensor
  • Volt free contacts
  • Oil temperature displays
  • Local annunciator
  • EMCP 4.3, EMCP 4.4
  • Local alarm horn
  • Remote annunciator

Starting/Charging
  • Oversize batteries
  • Battery chargers
  • Jacket water heater
  • Heavy-duty starting system
  • Charging alternator

Cooling System
  • Low coolant temperature alarm
  • Stone guards
  • Radiator duct flange

General
  • Narrow, Wide or Skid Base
  • Single or dual wall integral fuel tanks
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • The following options are based on regional and product configuration:
  • Automatic transfer switches (ATS)
  • Integral & sub-base UL listed dual wall fuel tanks
  • CSA Certification
  • EEC Declaration of Conformity
  • Single or dual wall sub-base fuel tanks
  • UL 2200 package
  • Sound attenuated, weather protective or high ambient weather protective enclosure
  • EU Certificate of Conformance (CE)

Enclosures
  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures

Exhaust System
  • 6 and 8 inch elbow kit
  • Manifold and turbocharger guard
  • End in / End out mufflers - 10, 25 and 35 dBA attenuation
  • Engine mounted muffler
  • 6 and 8 inch flange GP
  • Flexible exhaust fittings

Fuel System
  • Fuel transfer system controls
  • Manual fuel transfer pump
  • Dual wall fuel tank base

Lube System
  • Manual sump pump

Mounting System
  • Narrow skid base - replaces standard fuel tank base

Special Test / Reports
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor

Starting / Charging System
  • 5 Amp single battery charger
  • Jacket water heater
  • Battery disconnect switch

Application Centre

Explore valuable resources for generator sizing, specification, and training materials. SpecSizer evaluates load types, collects data, and organises it to help you select the generator set that's best for you. Find product comparisons, technical data, product sizing, and more using our technical information portal (TIP) specifically created for consultants, architects, engineers, and owners.

visit page

Why Choose Cat® Electric Power?

Caterpillar offers a comprehensive variety of electric power systems, customised to fit your needs. Our specialised systems deliver high power and performance in industries across the globe. With Caterpillar, you get outstanding manufacturing quality, expert support, and the essential tools and applications to complete any project.

Learn More About Electric Power

EMCP 4 Generator Set Controls

Cat generator sets provide a complete factory-built solution with fully featured standard and advanced controls. Optional accessories enhance the capabilities of the genset package-mounted control system.

Learn More