C32 (60 Hz) with Upgradeable Packaging

< Back

Financing & Insurance
See our Offers
View Product Downloads
Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

Overview

Producing reliable power from 830 to 1000 ekW at 60 Hz, our C32 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 per cent rated load in one step. Generator sets offer both low fuel consumption and low emission systems.

Generator Set Specifications

Units:
Minimum Rating 830 ekW 830 ekW Less
Maximum Rating 1000 eKW 1000 eKW Less
Emissions/Fuel Strategy Low Fuel, Low Emissions Low Fuel, Low Emissions Less
Voltage 220 to 600 Volts 220 to 600 Volts Less
Frequency 60 Hz 60 Hz Less
Speed 1800 rpm 1800 rpm Less
Duty Cycle Standby, Mission Critical, Prime, Continuous Standby, Mission Critical, Prime, Continuous Less

Engine Specifications

Engine Model C32 TA, V-12, 4-Stroke Water-Cooled Diesel C32 TA, V-12, 4-Stroke Water-Cooled Diesel Less
Bore 5.71 in 145.0 mm Less
Stroke 6.38 in 162.0 mm Less
Displacement 1958.9 in³ 32.1 l Less
Compression Ratio 15.0:1 15.0:1 Less
Aspiration TA TA Less
Fuel System MEUI MEUI Less
Governor Type Adem™A4 Adem™A4 Less

Generator Set Dimensions

Length - Maximum 165.3 in 4198.0 mm Less
Width - Maximum 66.3 in 1685.0 mm Less
Height - Maximum 85.1 in 2162.0 mm Less
Dry Weight - Genset (maximum) 14690.0 lb 6663.0 kg Less

Cat Generator Set Package

Cat Diesel Engine

SR5 Alternator

EMCP 4 Control Panel

Cooling System

Certifications

One Safe Source

World Wide Product Support

C32 (60 Hz) with Upgradeable Packaging Standard Equipment

Air Inlet System
  • Air Cleaner; single element canister type with service indicator

Control System
  • Local Annunciator
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • Text alarm/event descriptions
  • Customer data link (Modbus RTU)
  • Reverse Power (kW) (32)
  • Volts (L-L & L-N)
  • kVAr-hr (total)
  • kW (per phase, average & percent)
  • High coolant temperature
  • Low oil pressure
  • RTD module
  • Accessory module data link
  • Run / Auto / Stop Control
  • 2 programmable relay outputs (Form C)
  • Over/Under Frequency (81 o/u)
  • 6 programmable digital inputs
  • Emergency stop pushbutton
  • Overspeed
  • EMCP 4.2
  • Communications:
  • Low coolant level
  • Reverse Reactive Power (kVAr) (32RV)
  • kW-hr (total)
  • Generator phase sequence
  • kVA (per phase, average & percent)
  • Oil pressure (psi, kPa or bar)
  • 2 programmable digital outputs
  • Frequency (Hz)
  • kVAr (per phase, average & percent)
  • Remote serial annunciator
  • Thermocouple module
  • Engine cycle crank
  • Failure to start (overcrank)
  • 4 programmable relay outputs (Form A)
  • Coolant temperature
  • Over/Under voltage (27 / 59)
  • 24-volt DC operation
  • True RMS AC metering, 3-phase, �1% accuracy
  • Compatible with the following optional modules:
  • Digital I/O module
  • DC volts
  • Speed adjust
  • Overcurrent (50 / 51)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Operating hours
  • Remote CAN annunciator
  • RPM
  • Serial annunciator module data link
  • Programmable protective relaying functions:
  • Low coolant temperature
  • Features:
  • Environmental sealed front face
  • Digital indication for:
  • Emergency stop
  • Voltage adjust

Governing System
  • ADEM(tm) A4

Cooling System
  • Coolant drain line with valve
  • Radiator fan and fan drive
  • Caterpillar Extended Life Coolant
  • Low coolant level sensor
  • Fan and belt guards

Exhaust System
  • Exhaust manifold - dry - single - 8 in
  • 203 mm (8 in) ID round glanged outlet

Fuel System
  • Secondary fuel filters
  • Fuel priming pump
  • Fuel cooler
  • Primary fuel filter with water separator

Generators and Attachments
  • Integrated Voltage Regulator (IVR) - IVR includes reactive droop
  • NEMA Class H insulation, Class H temperature rise at 40C ambient
  • NEMA Class H insulation, Class H temperature rise at 40C ambient
  • Reactive droop
  • Random wound
  • Bus bar connections, top center mounted, top cable entry
  • 6 Lead
  • Form Wound
  • Low Voltage:
  • Permanent Magnet
  • 60 Hz models: NEMA standard hole pattern
  • Medium Voltage:
  • Winding temperature detectors
  • 3 Phase brushless, salient pole
  • Winding temperature detectors
  • Internal Excitation
  • Bus bar connections, right side extension box, bottom cable entry
  • 60 Hz models: NEMA standard hole pattern

Literature
  • English

Lube System
  • Oil filter, filler and dipstick
  • Oil drain lines and valve
  • Fumes disposal
  • Lubricating oil
  • Integral lube oil cooler
  • Gear type lube oil pump

Mounting System
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - Engine / generator / radiator mounting

Starting / Charging System
  • Battery disconnect switch
  • 45 Amp charging alternator
  • Battery, rack and cables
  • 24 Volt electric starting motor

General
  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • SAE standard rotation
  • Right hand servicing
  • Flywheel and flywheel housing-SAE No. 0 with SAE No. 0 to 00 adapter

C32 (60 Hz) with Upgradeable Packaging Optional Equipment

Control System
  • Governors
  • Expansion I/O module
  • Local annunciator module
  • Remote monitoring software
  • Remote annunciator module
  • Auxiliary box
  • Generator temperature monitoring
  • EMCP 4.3, EMCP 4.4
  • Customer interface options
  • Remote annunciator module
  • Local annunciator module
  • EMCP (4.2) (4.3) (4.4)

Control Panel Options
  • Local PC monitoring
  • Remote speed adjust
  • Vandal proof door
  • Panel lights
  • Auxiliary panel mounting locations

Cooling System
  • Radiator duct flange

Enclosures
  • Sound attenuated enclosures
  • Premium sound attenuated enclosures

Engine Options
  • Muffler (industrial grade)
  • Heavy duty electric starting motors
  • Heavy duty air cleaners
  • Spring type anti-vibration mounts (95% efficient)
  • Dual element air cleaners
  • Exhaust guards / shields
  • Battery Charger (10A)
  • Jacket water heater
  • Radiator duct flange
  • Rubber anti-vibration mounts (90% efficient)
  • Heavy Duty Batteries
  • Exhaust guards / shields
  • Radiator duct flange
  • Muffler (industrial grade)
  • Heavy duty electric starting motors
  • Dual element air cleaners
  • Heavy duty air cleaners

Extended Service Contract
  • 2 Year Extended Service Contract (ESC)
  • 5 Year Extended Service Contract (ESC)
  • 3 Year Extended Service Contract (ESC)

Exhaust System
  • Muffler installation kits
  • Elbows
  • Flanges
  • Guard and shield system
  • Flexible fittings
  • Flange and exhaust expanders
  • Mufflers

Factory Support
  • Factory commissioning

Generators and Attachments
  • Anti-condensation heaters
  • Temperature Rise over 40°C ambient: [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
  • Winding: [ ] Random [ ] Random with coastal insulation [ ] Form

Lube System
  • Oil level regulator
  • 186 liter oil pan
  • Prelube pumps

Mounting System
  • Radiator isolators
  • Spring type vibration isolator
  • Standard package isolators

Power Termination
  • Busbars
  • Circuit breaker, 100% Rated, UL Listed (fully rated)
  • Circuit breaker, IEC listed (fully rated)

Premium Enclosures
  • AC Panel, outlets and lights
  • Cold weather bundle - AC Panel, outlets, lights, heater motorized louvers, installed battery charger, heavy duty batteries, dual starters, jacket water heater, generator space heaters
  • DC lighting package
  • Colors - Yellow, White, Beige, Grey
  • Motorized louvers
  • Premium enclosure fuel tank options
  • Panel bracket
  • Fixed louvers - standard

Special Tests / Reports
  • CSA test and certification
  • PGS test report @ 1.0 power factor
  • Neutral grounding connection
  • Generator test report
  • Standard genset TVA report
  • PGS test report @ 0.8 power factor

Generators
  • Temperature Rise over 40°C ambient: [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C
  • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
  • Winding: [ ] Random [ ] Random with coastal insulation [ ] Form

Why Choose Cat® Electric Power?

Caterpillar offers a comprehensive variety of electric power systems, customised to fit your needs. Our specialised systems deliver high power and performance in industries across the globe. With Caterpillar, you get outstanding manufacturing quality, expert support, and the essential tools and applications to complete any project.

Learn More About Electric Power

EMCP 4 Generator Set Controls

Cat generator sets provide a complete factory-built solution with fully featured standard and advanced controls. Optional accessories enhance the capabilities of the genset package-mounted control system.

Learn More

Application Center

Explore valuable resources for generator sizing, specification, and training materials. SpecSizer evaluates load types, collects data, and organises it to help you select the generator set that's best for you. Find product comparisons, technical data, product sizing, and more using our technical information portal (TIP) specifically created for consultants, architects, engineers, and owners.

visit page