Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

C9 (50 Hz)Standard Equipment

Air Inlet System
  • Air cleaner, light duty with disposable paper filter

Control Panels
  • EMCP4.4 control panel

Cooling System
  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant

Exhaust System
  • Stainless steel exhaust flex, gaskets, rain cap and SAE exhaust
  • Flange for customer; shipped loose

Fuel System
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Generators and Generator Attachments
  • 12 leads
  • IP23 protection
  • Voltage regulator (single phase sensing)
  • Power centre, IP22
  • Segregated low voltage (AC/DC) wiring panel
  • Mandatory option circuit breaker, IEC, 3 pole

Governing System
  • Cat electronic governor (ADEM A4)

Lube System
  • Oil cooler
  • Lubricating oil
  • Oil drain valves

Mounting System
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines

Starting / Charging System
  • 24V battery with rack and cables

General
  • Engine and alternator re-paint, Caterpillar Yellow

C9 (50 Hz)Optional Equipment

Certifications
  • European Certifications
  • Global Certifications

Air inlet system
  • Single element air cleaner

Control Panels
  • Volt free contact
  • Local alarm horn
  • Oil temperature displays
  • Earth fault relay
  • Earth leakage ground fault relay
  • Overload alarm switch
  • Low fuel level alarm
  • Low fuel level shutdown
  • High fuel level alarm
  • Fuel level sensor

Control System
  • Stone guard / radiator trans flance
  • Low coolant temperature alarm

Enclosures
  • High ambient sound attenuated enclosure
  • Sound attenuated enclosure

Exhaust System
  • Muffler - 10 dBA attenuation
  • Muffler - 25 dBA attenuation

Fuel
  • Integral duel wall fuel tank base

Generators
  • Permanent magnet generator
  • LC frame generator

Mounting System
  • Narrow skid base

Special Packing / Inspectons for Shipment
  • Special tests / reports
  • Special packing for shipping
  • Special inspections

Starting / Charging
  • Battery charger 5 amp single
  • Battery removal
  • Battery disconnet switch
  • Jacket water heater

Overview

Producing reliable power from 230 kVA to 330 kVA at 50 Hz, our C9 diesel generator sets are made to meet your standby and prime applications. Each is designed to meet ISO 8528-5 transient response requirements and accept 100 percent rated load in one step. All C9 generator sets are engineered to EPA Stationary Emergency (Tier 3) emissions standards — it’s how we’re helping protect and power the world you live in. Seismic certification is also available to maintain power during unexpected disturbances. Our integrated control system, including ATS and switchgear, ensures a consistent power supply and connection to your fleet through on-site and remote monitoring options. The EMCP 4 control panel, with a user-friendly interface, puts our management and diagnostic tools in one. We offer a wide range of accessories and bolt-on system expansion attachments so you can adapt your generator sets to your needs. Find flexible packaging options to work with your spatial requirements and environmental conditions. Even select from UL 2200 and CSA certified package options for added safety. Tailor your C9 generator sets to take on today’s power needs — and tomorrow’s.

Generator Set Specifications

Units:
Minimum Rating 230 kVA 230 kVA Less
Maximum Rating 330 kVA 330 kVA Less
Voltage 220-480 Volts 220-480 Volts Less
Frequency 50 Hz 50 Hz Less
Speed 1500 RPM 1500 RPM Less

Generator Set Configurations

Emissions/Fuel Strategy EU Stage IIIA, Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards) EU Stage IIIA, Low Fuel Consumption, U.S. EPA Certified for Stationary Emergency Use only ( Tier 3 Nonroad Equivalent Emission Standards) Less

Engine Specifications

Engine Model C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel Less
Compression Ratio 16.1:1 16.1:1 Less
Aspiration Air to Air Aftercooled Air to Air Aftercooled Less
Governor Type Adem™A4 Adem™A4 Less
Fuel System Hydraulic electronic unit injection Hydraulic electronic unit injection Less
Bore 4.41 in 112.0 mm Less
Displacement 537.01 in³ 8.8 L Less
Stroke 5.87 in 149.0 mm Less

Cat Generator Set Packages

Cat® generator set packages have been fully prototype tested, and certified torsional vibration analysis reports are available. The packages are designed to meet the NFPA 110 requirement for loading, and conform to the ISO 8528-5 steady state and transient response requirements.

Cat Diesel Engines

The four cycle Cat diesel engine combines consistent performance with excellent fuel economy and transient response that meets or exceeds ISO 8528-5. The engines have been designed and built for a wide range of applications and can be optimized for low fuel consumption or low emissions. The engines feature a reliable, rugged, and durable design that has been field proven in thousands of applications worldwide from emergency standby installations to continuously operating power plants.

Cooling System

The cooling system has been designed to operate in standard ambient temperatures up to 50°C (122°F) with an air flow restriction of 0.5 in water. The factory installed cooling system has been designed and tested to ensure proper generator set cooling, and includes the radiator, fan, belts, and all guarding installed as standard. Contact your Cat Dealer for specific ambient and altitude capabilities.

Generators

The generators used on Cat packages have been designed and tested to work with the Cat engine. The generators are built with robust Class H insulation and provide industry leading motor starting capability. They provide high efficiency in a majority of applications and optional coastal protection for the windings is available for harsh environments.

Cat EMCP Control Panel

The EMCP controller features the reliability and durability you have come to expect from your Cat equipment. EMCP4 is a scalable control platform designed to ensure reliable generator set operation, providing extensive information about power output and engine operation. EMCP4 systems can be further customized to meet your needs through programming and expansion modules.

World Wide Product Support

Cat Dealers provide extensive post sale support including maintenance and repair agreements. Cat dealers have over 1,800 dealer branch stores operating in 200 countries. The Caterpillar S•O•S℠ program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products.