Electric Power Generation C7.1 (60 Hz) 120 kW - 175 kW Diesel Generator Set

Minimum Rating
120 ekW
120 ekW
Maximum Rating
175 ekW
175 ekW
Emissions/Fuel Strategy
Non Regulated
Non Regulated

Product Specifications for C7.1 (60 Hz)

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

C7.1 (60 Hz) Standard Equipment

Air Inlet System

  • Air Cleaner; light duty with disposable element
  • Air Cleaner; light duty with disposable element

Control Panels

  • EMCP 4.1
  • EMCP4.1 control panel

Cooling System

  • Fan drive, battery charging alternator drive
  • Coolant drain line with valves
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Radiator and cooling fan with guards

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use; shipped loose

Fuel System

  • Base, formed steel with single wall integral 8-hour fuel tank
  • Standard open set fuel tank / base supplied
  • Standard open set fuel tank / base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Lube System

  • Oil drain line with valve
  • Lubricating oil
  • Oil drain line with valve
  • Lubricating oil

Generator and Generator Attachments

  • Voltage regulator (single phase sensing)
  • 12 leads
  • Tower panel, IP22, bottom cable entry
  • IP23 protection
  • Segregated low voltage (AC/DC) wiring panel
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • IP23 protection
  • Tower panel, IP22, bottom cable entry
  • 12 leads

Mounting System

  • Includes lifting provision and drag points
  • Termination points for coolant and lube oil drain lines
  • Captive linear vibration isolators between base and engine-generator
  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provision and drag points

Packaged Generator Set

  • Flexible fuel lines to base NPT connections
  • Standard ambient temperatures up to 50°C (122°F)
  • Radiator and cooling fan complete with protective guards
  • Class H insulation
  • Drip proof generator air intake (NEMA 2, IP23)

Starting / Charging System

  • 24V battery with rack and cables

Governing System

  • Mechanical and electrical governing system - model dependent
  • Mechanical and electrical governing system - model dependent

General

  • Engine and alternator pre-paint, Caterpillar Yellow
  • Engine and alternator pre-paint, Caterpillar Yellow

C7.1 (60 Hz) Optional Equipment

Alternator System

  • Permanent magnet
  • 3 Phase sensing
  • Optional LC frame alternators
  • Alternator removal
  • Quatrature droop king
  • R frame auxiliary winding: R2273L4 SE aux alt 07, aux alt 08 and aux alt 10
  • Anti-condensation heater
  • Optional LC frame alternator with coastal insulation protection

Packaged Generator Set Options

  • Radiator stone guard

Circuit Breakers

  • Padlockable breaker device
  • 4 Pole 250A, 400A and 630A Circuit Breakers

Control System

  • Volt free contacts for common alarm
  • EMCP 4.2
  • Volt free contacts for generator set running
  • Static battery charger
  • Control panel heater

Control Panel Options

  • Volt free contacts
  • Speed adjust potentiometer
  • Battery charger
  • Panel mounted audible alarm
  • Emergency stop with key
  • Speed adjust contacts
  • Overload shutdown via breaker
  • Control panel heater
  • Earth fault (2 wire only)
  • Earth leakage (2 wire only)
  • Speed adjust contacts
  • Battery charger
  • Earth fault (2 wire only)
  • Earth leakage (2 wire only)

Cooling System

  • Low coolant temperature
  • Coolant heater
  • Low coolant level shutdown
  • Low coolant level shutdown

Enclosures

  • Sound attenuated levels 1 and 2 enclosures
  • Rental options (CAE only) - Single point lift
  • Rental options (CAE only) - CEE form sockets for enclosure
  • Rental options (CAE only) - Socket blanking plate
  • Rental options (CAE only) - Rental pack
  • Rental options (CAE only) - Socket blanking plate
  • Rental options (CAE only) - CEE form sockets for enclosure
  • Sound attenuated level 2 enclosure

European Certifications

  • Upgrade to STD set for CE

Mounting Options

  • Silencer installation kit
  • Industrial silencer removal
  • Residential silencer
  • Battery removal
  • Electronic governor
  • Electronic governor

Test Reports

  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor

General

  • Stone guards / radiator trans flange

Fuel Systems

  • Low fuel level shutdown
  • DEFRA bunded fuel tank
  • Open set narrow tankbase
  • Compact skidbase for open sets
  • Skidbase for CALG enclosure sets
  • Low fuel level alarm
  • High fuel level alarm
  • Low fuel level shutdown
  • Low fuel level alarm
  • Compact skidbase for open sets

Global Certifications

  • Certification for CIS
  • Certification for CIS

Power Termination

  • Circuit breaker, IEC, 4 pole

Accessories / Miscellaneous

  • Packing case - compact set
  • Packing case - canopied set

See how C7.1 (60 Hz) compares against frequently compared products.

Tools And Expert Help At Every Turn

Information Library

We have an information library of product literature, white papers, customer stories, and more. Find what you’re looking for.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Hire Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for hire.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

Extended Service Coverage

Spend less time managing your equipment and more time running your business with options to protect you against unexpected repair costs.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Check out current offers for the C7.1 (60 Hz)

View More Offers