G3520EStandard Equipment

Air Inlet
  • Two-element single-stage air cleaner with enclosure and service indicator

Control Panels
  • EMCP II+

Cooling
  • Engine driven water pumps for jacket water and after cooler
  • Jacket water and SCAC thermostats
  • ANSI/DN customer flange connections for JW inlet and outlet

Exhaust
  • Dry exhaust manifolds, insulated and shielded
  • Center section cooled turbocharger with Cat flanged outlet
  • Individual exhaust port and turbocharger outlet wired to Integrated Temperature Sensing Module (ITSM) with GECM providing alarms and shutdowns

Fuel system
  • Throttle plate, 24V DC actuator, controlled by GECM
  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Electronic fuel metering valve

Generator
  • SR4B
  • Caterpillar's Digital Voltage Regulator (CDVR) with 3-phase sensing and KVAR/PF control
  • Bus bar connections
  • Anti-condensation space heater
  • Reactive droop
  • Winding temperature detectors

Starting/Charging
  • 24V starting motors
  • Battery with cables and rack(shipped loose)
  • Battery disconnect switch
  • 60A, 24V charging alternator (standard on 60Hz 1800 rpm only)

General
  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Crankshaft vibration damper and guard
  • Operation and maintenance manuals
  • Parts book

G3520EOptional Equipment

Air Inlet
  • Mounting stand
  • Air cleaner with precleaner

Control Panels
  • Local alarm module
  • Remote annuciator
  • Remote Communications Module (PL1000T, PL1000E)
  • Synchronizing module
  • Engine failure relay

Cooling
  • Remote radiator for JW and SCAC circuits, level switch included but not wired
  • Coolant level drain line with valves, fan with guard
  • Inlet/Outlet connections

Exhaust
  • Flange
  • Exhaust expander
  • Elbow
  • Flexible fitting
  • Muffler and spark-arresting muffler with companion flanges

Fuel System
  • Fuel filter
  • Gas pressure regulator
  • Gas shutoff valve 24V, ETR (Energized-To-Run)

Generator
  • Low voltage extension box
  • Cable access box
  • Bearing temperature detectors
  • European bus bar
  • Generator air filter
  • Medium and high voltage generators and attachment
  • Manual voltage control

Start/Charging
  • Battery charger
  • Oversized battery
  • Jacket water heater
  • Charging alternator

General
  • Crankcase explosion relief valve
  • Engine barring group
  • EEC D.O.I and other certifications