XQP150 - Diesel

< Back

Financing & Insurance
See our Offers
View Product Downloads
Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

Overview

The 150 kVA model comes in two versions. The Stage IIIA product is emission-optimized and legally required on all mobile applications in Europe, while the fuel-optimized product is ideal for customers interested in consuming the least amount of fuel. Each model delivers increased flexibility by easily switching between 50 and 60 Hz, which allows one machine to satisfy varying load requirements across diverse regions and applications including mining, manufacturing, oil and gas and construction.

Generator

Units:
Rating Prime 150 kVA 150 kVA Less
Frequency 50/60 Hz 50/60 Hz Less
Voltage 127 - 480 V 127 - 480 V Less

Engine

Engine C7.1 Diesel Engine or C7.1 ACERT Diesel Engine C7.1 Diesel Engine or C7.1 ACERT Diesel Engine Less
Fuel Diesel Diesel Less

Dimensions

Width 44.1 in 1120.0 mm Less
Height 87.6 in 2226.0 mm Less
Length 138.6 in 3520.0 mm Less
Weight 5615.0 lb 2547.0 kg Less

Fuel Consumption EU Stage IIIA

100% Load 50Hz 9.9 gal/hr 37.5 l/hr Less
100% Load 60Hz 11.2 gal/hr 42.3 l/hr Less
75% Load 50Hz 7.8 gal/hr 29.6 l/hr Less
75% Load 60Hz 9.2 gal/hr 34.7 l/hr Less
50% Load 50Hz 5.4 gal/hr 20.3 l/hr Less
50% Load 60Hz 6.3 gal/hr 23.8 l/hr Less

Fuel consumption Best Fuel Efficiency

100% Load 50Hz 8.8 gal/hr 33.3 l/hr Less
100% Load 60Hz 10.5 gal/hr 38.2 l/hr Less
75% Load 50Hz 6.5 gal/hr 24.7 l/hr Less
75% Load 60Hz 7.7 gal/hr 29.1 l/hr Less
50% Load 50Hz 4.3 gal/hr 16.4 l/hr Less
50% Load 60Hz 5.0 gal/hr 19.1 l/hr Less

Noise rating (with enclosure) EU Stage IIIA

Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) 73.1 dB(A) 73.1 dB(A) Less
Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) 76.4 dB(A) 76.4 dB(A) Less

Noise rating (with enclosure) Best Fuel Efficiency

Sound Power @ 1 meters (3 feet) @ 75% of rating (50Hz) 74.7 dB(A) 74.7 dB(A) Less
Sound Power @ 1 meters (3 feet) @ 75% of rating (60Hz) 78.3 dB(A) 78.3 dB(A) Less

Rental ready

Robust, durable product with a range of rental ready features to meet job requirements and applications.

Fuel/Emissions Strategy

Emissions Equivalent to EU Stage IIIA and Best Fuel Efficiency.

Cat C7.1 Diesel Engine

Industry proven reliability.

Cat EMCP 4.2B Control Panel

Easy to use digital controls.

Cat LC3114J Generator

Integrated voltage regular for fast response in demanding applications.

Robust Galvanised Enclosure

Inhibits corrosion in service. Prevents water ingress, provides security and sound attenuation.

Sound Isolated Operator Panel

Improved operator comfort.

Cat Connect

Remote monitoring for fleet management and asset tracking.

Factory Designed, Built and Tested

Supported by an industry leading global dealer network.

Additional Options Available

Synchronising controls. Distribution sockets. Extended Service interval kits.

XQP150 - Diesel Standard Equipment

CAT C7.1 Diesel Engine
  • Turbo charged.

Generator
  • LC3114J frame.

Air Filter
  • Cyclonic/paper with dust cup and service indicator.

Cat Connect remote monitoring
  • Provides package monitoring and management.

Cooling System
  • Package mounted radiator with vertical air discharge. Filled from factory.

Charging / Starting System
  • 12V heavy duty starting motor and charging alternator c/w battery isolator.

Fuel System
  • 24hr dual wall fuel tank with 3 way directional valve for external supply.

Control Panel
  • Digital EMCP4.2B set mounted controller.

Distribution
  • Single, robust enclosure for controls and distribution c/w 4 pole circuit breaker and safety cut off.

Structure
  • Heavy Duty steel base frame with integral fuel tank. Fork lift pockets. Dragging bars. Lifting frame and 4 point lift. Base frame is wider than enclosure to protect generator set during transportation.

Enclosure
  • Sound attenuating, galvanised steel enclosure with exceptional noise reduction performance.

Exhaust
  • Integrated spark arresting silencer.

Lube Oil
  • On engine primary and secondary oil filters. Filled from factory.

General
  • Factory tested and inspected.

EMCP 4 Generator Set Controls

Cat generator sets provide a complete factory-built solution with fully featured standard and advanced controls. Optional accessories enhance the capabilities of the genset package-mounted control system.

Learn More

Why Choose Cat® Electric Power?

Caterpillar offers a comprehensive variety of electric power systems, customized to fit your needs. Our specialized systems deliver high power and performance in industries across the globe. With Caterpillar, you get outstanding manufacturing quality, expert support, and the essential tools and applications to complete any project.

Learn More About Electric Power

Application Center

Explore valuable resources for generator sizing, specification, and training materials. SpecSizer evaluates load types, collects data, and organizes it to help you select the generator set that's best for you. Find product comparisons, technical data, product sizing, and more using our technical information portal (TIP) specifically created for consultants, architects, engineers, and owners.