Key Specs

Minimum Rating
1045 ekW
1045 ekW
Maximum Rating
1245 ekW
1245 ekW
Emissions
Non-certified
Non-certified

Overview

Oil and gas drilling is a complex task that requires specialized power generation equipment. Cat 3500 power modules are specifically designed for drilling operations of electric AC rigs. They combine decades of field experience of the 3500 platform with the latest electronics to ensure highest performance, low emissions, and simplified operator interface. Cat power modules are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. 3512B land drilling power module ratings: 1045-1245 ekW (1492-1750 kVA) @ 50/60 Hz (1200/1500 rpm). Not emissions certified, available for non-regulated areas.

Product Specifications for 3512B

Minimum Rating 1045 ekW 1045 ekW
Maximum Rating 1245 ekW 1245 ekW
Emissions Non-certified Non-certified
Oil Change Interval 500 h 500 h
Bore 6.69 in 170 mm
Fuel System EUI EUI
Engine Control and Protection ADEM A3 ADEM A3
Generator SR4B SR4B
Displacement 3158 in³ 52 l
Stroke 7.48 in 190 mm
Generator Set Control EMCP 4.3 EMCP 4.3
Weight 30864 lb 14000 kg
Voltage 600 600
Aspiration Turbocharged-Aftercooled Turbocharged-Aftercooled
Height 104.7 in 2659 mm
Width 91.2 in 2318 mm
Length 238.2 in 6051 mm
Cooling System - Engine 41 gal (US) 157 l
Lube Oil System - Refill 84 gal (US) 318 l

3512B Standard Equipment

Air Inlet System

  • Corrosion-resistant aftercooler core
  • Air Inlet shutoff
  • Regular duty air cleaner

Control System

  • ADEM A3 ECU, left-hand mounted
  • Direct rack control 0-200 mADC, space heater and jacket water heater connection and controls

Cooling System

  • Caterpillar supplied radiator, 46/CVS-stacked 0.627 ratio, includes blower fan, fan drive, pulley, belt guard, coolant level sensor, regulator, and fuel cooler
  • Separate-circuit aftercooled
  • Outlet controlled jacket water thermostat
  • Jacket water pump - gear driven
  • Dual outlet
  • Aftercooler water pump - gear driven
  • Aftercooler water thermostat

Exhaust System

  • Dry exhaust manifold
  • Dual turbochargers, water cooled bearings

Flywheel and Housing

  • SAE No. 00 flywheel
  • SAE No. 00 flywheel housing
  • SAE standard rotation

Fuel System

  • Fuel filter simplex (LH) with priming pump (LH)
  • Fuel transfer pump
  • Fuel return line with flexible connection
  • Electronic unit injectors

Generator Attachments

  • Barrel-mounted petroleum terminal box with air filter and pressure differential switch

Instrumentation

  • Emergency stop button
  • Analog gauges:
  • Service port connector
  • Customer connection terminal blocks

EMCP 4.3 Control Panel

  • 140 mm (5.5 in) Graphical Display
  • Communication
  • Controls
  • Generator Set Protection
  • Outputs
  • Inputs
  • Other Features

Lubrication System

  • Crankcase breather
  • Oil cooler
  • Shallow oil pan
  • Oil drain extension, 2 in NPT female connection
  • Simplex oil filter

Mounting System

  • 4.19 m (165 in) length, 412 mm (16.2 in) height tubes, 1.18 m (50.5 in) wide

Protection System

  • Engine alarms, derate, and shutdown in abnormal operation

Starting System

  • TDI air starting motor, RH - 1034 kPa (150 psi)

General

  • Paint - Cat yellow

3512B Optional Equipment

Air Inlet System

  • Heavy duty air cleaner
  • Remote air inlet adapter - rectangular
  • Remote air inlet adapter - round

Control System

  • Engine control options:
  • Load sharing governor, 2301A

Cooling System

  • Radiator options:
  • Coolant level sensor
  • Coolant conditioner
  • Cooling system connection options (for use with customer-supplied radiator):
  • Fan drive and belt guard (for use with remote and customersupplied radiators)
  • Fan pulley options (for use with customer-supplied radiator):

Exhaust System

  • 1200 rpm model only:
  • 1500 rpm model only:

Fuel System

  • Custom fuel filter
  • Primary fuel filter
  • Primary fuel filter with water separator

Generator Attachments

  • Barrel-mounted petroleum terminal box
  • Current transformers (3)
  • Cable access box

Instrumentation

  • Communications module PL1000T
  • Communications module PL1000E
  • Thermocouples installed, one per cylinder

Lubrication System

  • Custom oil filter
  • RH installed centrifugal oil filter
  • SAE15W40, Caterpillar DEO, 500 hour
  • Crankcase fumes disposal
  • Oil level regulator

Mounting System

  • Custom inner base
  • Custom outer base
  • Package isolator supports (3), for mounting inner base to customer-supplied base

Power Take-off

  • Alternator, 24V, 68A

Protection System

  • Explosion relief valves (3)
  • Metal particle detector switch
  • Metal particle detector with annunciator

Starting System

  • Custom starting motor
  • Air pressure regulator

General

  • LH installed engine barring group
  • Jacket water heater, UL recognized, 120-240V, single phase, 6 kW, LH and RH mounted
  • Jacket water heater, UL recognized, 120-480V, single phase, 12 kW, LH and RH mounted
  • Jacket water heater lines

See how 3512B compares against frequently compared products.

Use the comparison tool to compare detailed specs of Cat and competitor models.

COMPARE ALL MODELS

Tools And Expert Help At Every Turn

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.

Marketing Consent

Check out current offers for the 3512B

View More Offers