Rental Power

MOBILE GENERATOR SETS

The lifeblood of your business is reliable electric power. Mobile generators ensure that you'll never be without it. Connect a unit to your building. Take one to a remote location. Connect multiple units in parallel. Our natural gas and diesel mobile generators were engineered for easy transporting and fast installation.

60 Hz

28 - 1705 ekW

ekW Generator Set Model Configuration     Media
Standby Prime Contin.
31 28 XQP30 Low BSFC Link
60 54 XQP60 R96/EU Stage IIIA Equivalent Link
103 94 XQP100 Low BSFC Link
137 125 XQP115 EU Stage V Link
149 135 XQP150 Low BSFC Link
198 180 XQP200 EU Stage V Link
302 275 XQP300 Low BSFC Link
297 270 XQP310 EU Stage V Link
460 420 XQP500 Low BSFC Link
512 470 XQP550 EU Stage V Link
1067 970 XQP1100 Low BSFC Link
1260 XQC1200 Low BSFC, Low Emissions Link
1705 XQC1600 Low BSFC, Low Emissions Link

35 - 2500 kVA - EPA Tier 4 Final

kVA Generator Set Model Configuration     Media
Standby Prime Contin.
38 35 XQ35 EPA Tier 4 Final LEXExxxxx
60 XQ60 EPA Tier 4 Final  
138 125 XQ125 EPA Tier 4 Final  
250 228 XQ230 EPA Tier 4 Final  
360 330 XQ330 EPA Tier 4 Final  
469 425 XQ425 EPA Tier 4 Final  
625 568 XQ570 EPA Tier 4 Final  
1250 1136 XQ1140 EPA Tier 4 Final  
2500 2280 XQ2280 EPA Tier 4 Final  

50 Hz

20 - 1893 kVA

kVA Generator Set Model Configuration
Media
Standby Prime Contin.
22 20 XQP20 EU Stage V LEXExxxxx
33 30 XQP30 Low BSFC  
65 60 XQP60 R96/EU Stage IIIA Equivalent  
110 100 XQP100 Low BSFC  
125 114 XQP115 EU Stage V  
165 150 XQP150 Low BSFC  
220 200 XQP200 EU Stage V  
330 300 XQP300 Low BSFC  
340 310 XQP310 EU Stage V  
550 500 XQP500 Low BSFC  
605 550 XQP550 EU Stage V  
1210 1100 XQP1100 Low BSFC  
1438 XQC1200 Low BSFC / Low Emissions  
1893 XQC1600 Low BSFC / Low Emissions  

Standby: Output available with varying load for the duration of the interruption of the normal source power. Average power output is 70% of the standby rated ekW. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.

Mission Critical: Output available with varying load for the duration of the interruption of the normal source power. Average power output is 85% of the mission critical rated ekW. Typical peak demand up to 100% of rated ekW for up to 5% of the operating time. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.

Prime: Output available with varying load for an unlimited time. Average power output is 70% of the prime rated ekW. Typical peak demand is 100% of prime rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year.

Prime-DCP: For data center applications only. Prime-DCP power output available with varying load for unlimited time. Average power output is not to exceed 100% of Prime-DCP rated ekW. Typical peak demand is 100% of the prime-DCP rated ekW with 10% overload capability for emergency use for a maximum of 1 hour in 12. Overload operation cannot exceed 25 hours per year.

Continuous: Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous rated ekW. Typical peak demand is 100% of continuous rated ekW for 100% of the operating hours.

Standby Power Rating / Demand Response: Output available with varying load for the duration of the interruption of normal source power. Average power output is 70% of the standby rated ekW. Typical operation is 200 hours per year, with maximum expected usage of 500 hours per year.

Emergency Standby Power (ESP): Output available with varying loads for the duration of the interruption of the normal source power. Average power output is 70% of the ESP rated ekW. Typical operation is 50 hours per year with a maximum expected usage of 200 hours per year.

Prime Power Rating: Output available with varying load for an unlimited time. Average power output is 70% of the prime rated ekW. Typical peak demand is 100% of prime rated ekW.

Continuous Power Rating: Output available with non-varying load for an unlimited time. Average power output is 70-100% of the continuous rated ekW. Typical peak demand is 100% of continuous rated ekW for 100% of operating hours.

Related Content

Electric Power Ratings Guide

Download Now
Electric Power Ratings Guide
Electric Power Ratings Guide

Applications

Cat® Rental Power Solutions

See Video
Cat® XQ2280 mobile Generator
Cat® XQ2280 mobile Generator

Cat® XQ1140 Quick Start

Quick Start Video
Cat® XQ1140 Quick Start
Cat® XQ1140 Quick Start

Cat® XQ2280 mobile Generator

See Video
Cat® XQ2280 mobile Generator
Cat® XQ2280 mobile Generator

Sustainability

For Caterpillar, sustainability is not a new concept. It’s part of who we are and what we do every single day.

Learn More
Fill in Alt Text for SEO
Fill in Alt Text for SEO

Custom Power Solutions

Our team of experts is waiting to help you design a solution for your application, and no application is too challenging.

Learn More
Fill in Alt Text for SEO
Fill in Alt Text for SEO

Generator Set Sizing Calculators

Caterpillar Electric Power now has two tools available for sizing gensets in any application.

Size Now
Fill in Alt Text for SEO
Fill in Alt Text for SEO

Configure Your Generator

Build and customize your own Generator set to perfectly fit your needs.

Build Now
Fill in Alt Text for SEO
Fill in Alt Text for SEO

Search Available Stock

View your local dealer's inventory to fit your power needs.

Search Stock
Fill in Alt Text for SEO
Fill in Alt Text for SEO

Dealer Locator

Your Cat dealer is committed to maximizing your success, helping you get the most out of your operations with site-level solutions, service and support.

Find Dealer
Fill in Alt Text for SEO
Fill in Alt Text for SEO