Yes, I would like to receive future marketing communications (such as email) from Caterpillar Inc., its affiliates and subsidiaries worldwide and the Caterpillar dealer network. Regardless of whether you decide to receive these marketing communications, Caterpillar will continue to send service/transactional messages, including those that have to do with any accounts that you may have with us.

Overview

The 3516E diesel generator sets have been developed to meet your continuous, standby and prime applications and match your power standards. Producing reliable power from 2750 to 3000 kVA (3100 kVA without fan) at 50 Hz, each generator set has been designed to meet ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. The generator set offers a low fuel consumption system.

Generator Set Specifications

Units:
Minimum Rating 2750 kVA 2750 kVA Less
Maximum Rating 3000 kVA (3100 kVA without fan) 3000 kVA (3100 kVA without fan) Less
Emissions/Fuel Strategy Low Fuel Consumption Low Fuel Consumption Less
Voltage 380 to 11000 volts 380 to 11000 volts Less
Frequency 50 Hz 50 Hz Less
Speed 1500 rpm 1500 rpm Less
Duty Cycle Standby, Mission Critical, Prime Standby, Mission Critical, Prime Less

Engine Specifications

Engine Model 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel 3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel Less
Bore 6.69 in 170.0 mm Less
Stroke 8.46 in 215.0 mm Less
Displacement 4766.0 in 78.1 l Less
Compression Ratio 14:01 14:01 Less
Aspiration TA TA Less
Fuel System Electronic unit injection Electronic unit injection Less
Governor Type Adem™5 Adem™5 Less

Generator Set Dimensions

Length - Maximum 296.8 in 7538.0 mm Less
Width - Maximum 87.2 in 2216.0 mm Less
Height - Maximum 133.5 in 3391.0 mm Less
Dry Weight - Genset (maximum) 43541.0 lb 19750.0 kg Less

Cat Generator Set Package

Cat Diesel Engine

SR5 Alternator

EMCP 4 Control Panel

Cooling System

Certifications

One Safe Source

World Wide Product Support

3516E (50 Hz) Standard Equipment

Air Inlet System
  • Single element canister type with service indicator
  • Air cleaner

Air Inlet
  • Air Cleaner

Control Panel
  • EMCP 4 Genset Controller
  • Reverse reactive power (kVAr) (32RV)
  • RPM
  • 24-volt DC operation
  • Coolant temperature
  • Low oil pressure
  • kVA (per phase, average & percent)
  • Low coolant level
  • Generator mounted - rear facing
  • Over / under frequency (81 o/u)
  • Failure to start (overcrank)
  • Low coolant temperature
  • Operating hours
  • Engine cycle crank
  • Emergency stop pushbutton
  • Lamp test
  • Amps (per phase & average)
  • Programmable protective relaying functions:
  • Serial annunciator module data link
  • Over / under voltage (27/59)
  • Alarm acknowledge
  • Panel lights
  • kW-hr (total)
  • kW (per phase, average & percent)
  • Generator phase sequence
  • Engine cool-down timer
  • kVAr-hr (total)
  • EMCP4.2 controller includes:
  • Digital indication for:
  • Communications:
  • Reverse power (kW) (32)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Text alarm / event descriptions
  • Speed adjust
  • Volts (L-L & L-N)
  • High coolant temperature
  • 4 programmable relay outputs (Form A)
  • 6 programmable digital inputs
  • Oil pressure (psi, kPa or bar)
  • Controls:
  • Environmental sealed front face
  • Power Factor (per phase & average)
  • 2 programmable relay outputs (Form C)
  • kVAr (per phase, average & percent)
  • Accessory module data link
  • DC volts
  • Emergency stop
  • Customer data link (Modbus RTU)
  • Overspeed
  • 2 programmable digital outputs
  • Frequency (Hz)
  • Warning/shutdown with common LED indication of shutdowns for:
  • Overcurrent (50/51)
  • EMCP 4.2

Exhaust
  • Exhaust flange outlet

Fuel
  • Fuel priming pump
  • Secondary fuel filter
  • Primary fuel filter with integral water separator

Generator
  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Power Termination
  • Bus Bar

Starting/Charging
  • Heavy-duty starting system
  • Charging alternator

Cooling
  • Package mounted radiator

Cooling System
  • JWAC
  • Coolant drain line with valve
  • Caterpillar Extended Life Coolant
  • Coolant level sensors
  • Fan and belt guards
  • Radiator fan and fan drive

Exhaust System
  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator
  • Fuel priming pump

Generators and Attachments
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).
  • Bus bar connections, top center mounted, top cable entry
  • IEC standard hole pattern
  • Winding temperature detectors
  • 3 phase brushless, salient pole
  • 6 lead
  • Internal excitation
  • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
  • Random wound

Governing System
  • ADEM III

Literature
  • English

Lube System
  • Integral lube oil cooler
  • Oil drain lines and valve
  • Fumes disposal
  • Gear type lube oil pump
  • Lubricating oil
  • Oil filter, filler and dipstick

Mounting System
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - engine / generator / radiator mounting

Starting / Charging System
  • Battery disconnect switch
  • 24 Volt electric starting motor
  • Battery and battery rack w/cables

General
  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Right hand servicing
  • SAE standard rotation
  • Paint: Caterpillar yellow with high gloss black rails & radiator
  • Flywheel and flywheel housing-SAE No. 00

3516E (50 Hz) Optional Equipment

Air Inlet System
  • Air inlet protection
  • Heavy duty air cleaners
  • Remote air inlet adapters
  • Dual element air cleaners

Power Termination
  • Circuit breakers, IEC compliant

Circuit Breakers
  • Optional busbar power connections
  • Load take off; IEC standard hole
  • Center posts busbars
  • Control packaging for enclosures
  • Trip Units
  • EMAX breakers
  • Cable entry options

Control Panels
  • Generator temperature monitoring
  • Vandal proof panel door
  • Local and remote monitoring
  • Governors
  • Auxiliary box
  • Busbar connections
  • Customer interface options
  • Language options
  • Annunciator modules
  • Voltage raise / lower switch
  • Remote speed adjust
  • External box clips
  • EMAX breaker connections
  • EMCP 4.3, EMCP 4.4

Cooling System
  • Radiator duct flanges
  • Optional Serpentine radiators
  • Water level switch gauges
  • Heat exchangers

European Certifications
  • EU declaration of conformity

Exhaust System
  • Flexible fittings
  • Mufflers
  • Muffler mounting kits
  • Through wall installation kit

Fuel System
  • Primary fuel filter
  • Fuel coolers

Generators and attachments
  • Internal excitation
  • Random wound
  • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
     
  • Optional generators
  • 3 Phase, Random wound, Internal excitation
  • Number of leads: 6
  • Pitch: 0.6667

Instrumentation
  • Pyrometers and thermocouples
  • Thermocouples

Lube System
  • Electric prelube pumps
  • Oil level regulator
  • Manual prelube sump pumps

Mounting System
  • Spring type vibration isolators
  • IBC vibration isolators

Protection System
  • Explosion relief valves

Special Tests / Reports
  • CSA test and certification
  • PGS test report @ 1.0 power factor
  • IBC seismic certificate
  • Neutral ground certificate
  • PGS test report @ 0.8 power factor

Starting / Charging System
  • ETHER starting aids
  • Jacket water heaters
  • Dual 24 volt electric starting motors
  • 10 and 20 amp battery chargers
  • Charging alternators - 50 Amp
  • 24 Volt battery sets - Dry

General
  • Engine barring group

Why Choose Cat® Electric Power?

Caterpillar offers a comprehensive variety of electric power systems, customised to fit your needs. Our specialised systems deliver high power and performance in industries across the globe. With Caterpillar, you get outstanding manufacturing quality, expert support, and the essential tools and applications to complete any project.

Learn More About Electric Power

EMCP 4 Generator Set Controls

Cat generator sets provide a complete factory-built solution with fully featured standard and advanced controls. Optional accessories enhance the capabilities of the genset package-mounted control system.

Learn More

Application Center

Explore valuable resources for generator sizing, specification, and training materials. SpecSizer evaluates load types, collects data, and organises it to help you select the generator set that's best for you. Find product comparisons, technical data, product sizing, and more using our technical information portal (TIP) specifically created for consultants, architects, engineers, and owners.

visit page