Electric Power 3516 (50 Hz) 1600 - 2000 kVA Diesel Generator Set

Product Specifications for 3516 (50 Hz)

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

3516 (50 Hz) Standard Equipment

Air Inlet System

  • Air Cleaner; single element canister type

Air Inlet

  • Air Cleaner

Cooling

  • Package mounted radiator

Exhaust

  • Exhaust flange outlet

Fuel

  • Secondary fuel filter
  • Fuel priming pump
  • Primary fuel filter with integral water separator

Generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

Power Termination

  • Bus Bar

Control Panel

  • EMCP 4 Genset Controller

Control Panels

  • Over / Under voltage (27/59)
  • Serial annunciator module data link
  • Communications:
  • Overcurrent (50/51)
  • Over / Under frequency (81 o/u
  • Text alarm / event descriptions
  • Generator set packages include Caterpillar' s Voltage Regulator.
  • Programmable protective relaying functions:
  • 4 Programmable relay outputs (Form A)
  • Reverse Power (kW) (32)
  • Emergency stop
  • Amps (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • Operating hours
  • 24 Volt DC operation
  • Low oil pressure
  • 6 Customer programmable digital inputs
  • 1 Programmable digital outputs
  • 1 Programmable relay outputs (Form C)
  • Volts (L-L & L-N)
  • Number of I/O varies on options selected:
  • RPM - DC volts
  • Low coolant level
  • kVAr-hr (total)
  • Controls: Speed adjust - Auto / start / stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • kW-hr (total)
  • Failure to start (overcrank)
  • Environmental sealed front face
  • Power Factor (per phase & average)
  • Accessory module data link
  • Generator mounted - rear facing
  • High coolant temperature
  • Overspeed
  • 3 Analog inputs
  • Frequency (Hz)
  • Warning/shutdown with common LED indication of shutdowns for
  • Coolant temperature
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor
  • Customer data link (Modbus RTU)
  • kVA (per phase, average & percent)
  • Cat Connect
  • Generator phase sequence
  • Reverse Reactive Power (kVAr) (32RV
  • DC volts
  • kW (per phase, average & percent)
  • kVAr (per phase, average & percent)
  • Emergency stop pushbutton
  • Digital indication for
  • Low coolant temperature
  • EMCP 4.2

Cooling System

  • ATAAC - 3516E Package Radiators shipped installed
  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters

General

  • SAE Standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

  • Medium Voltage:
  • Form wound
  • Winding temperature detectors
  • High Voltage:
  • 3 Phase brushless, salient pole
  • Permanent magnet
  • Permanent magnet
  • NEMA standard hole pattern
  • Internal Excitation
  • Six lead
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Low voltage:
  • Winding temperature detectors
  • NEMA standard hole pattern
  • Form wound
  • Winding temperature detectors
  • Random wound
  • Busbar connections, top center mounted, top cable entry
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Anti Condensation Space Heater
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)

Governing System

  • ADEM A3

Literature

  • English

Lubrication System

  • Gear type lube oil pump
  • Fumes disposal
  • Oil drain lines and valve
  • Lubricating oil
  • Oil filter, filler and dipstick
  • Integral lube oil cool

Mounting System

  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - engine / generator / radiator mounting

Starting System

  • Battery disconnect switch
  • Battery and battery rack w/cables
  • 45 Amp charging alternator
  • 24 Volt electric starting motor

3516 (50 Hz) Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Exhaust

  • Exhaust mufflers

Cooling System

  • Optional installed radiators
  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Standard ambient radiators
  • Water level switch gauges

Generator

  • Internal excitation (IE)
  • Anti-condensation heater
  • Oversize and premium generators
  • Permanent magnet excitation (PMG)

Crankcase System

  • No explosion relief valves
  • Ventilation system
  • Explosion relief valves

Power Termination

  • Circuit breakers, UL listed
  • Circuit breakers, IEC compliant

Control Panels

  • Remote monitoring software
  • Generator temperature monitoring & protection
  • Load share module
  • EMCP 4.4
  • Digital I/O module
  • EMCP 4.3
  • EMCP 4.2

Exhaust System

  • Exhaust offset
  • Tier 4 dosing cabinet
  • Flexible fittings
  • Mufflers
  • Tier 4 clean emissions module
  • Elbows
  • Flange and exhaust expanders
  • Tier 4 clean emission MOD Kits
  • Flanges
  • Clean emission parts
  • Y-Adapters

Mounting

  • Spring-type vibration isolator
  • IBC isolators
  • Rubber anti-vibration mounts

Fuel System

  • Fuel Priming Pumps (Tier 4) - Manual or electric
  • Primary fuel filter

Starting/Charging

  • Jacket water heater
  • Oversize batteries
  • Battery chargers
  • Air starting motor with control and silencer
  • Heavy-duty starting system
  • Charging alternator

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Generators and Attachments

  • Thermostate for space heater
  • Alternator air cleaner
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Generator conversion
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Space heater

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • Spring type vibration isolators
  • Puck style low efficiency isolators
  • IBC vibration isolators

Power Connections

  • Neutral ground connections
  • Center post busbar
  • Right side power connections
  • Rear power connections
  • 2700 Frame, four lead, four terminal
  • Left side power connections
  • Ground cables between generator and terminal box
  • Low voltage circuit breakers

Special Tests / Reports

  • IBC certification
  • Standard engine test charge
  • PGS test report @ 1.0 power factor
  • generator test report
  • Fuel consumption test
  • Canadian Standards Association certification
  • PGS test report @ 0.8 power factor
  • OSHPD certification
  • Torsional vibration analysis reports
  • Generator set fuel consumption test

Starting and Charging

  • Electric starting motors
  • Air pressure regulator
  • 24 Volt battery set - Dry
  • Engine barring device
  • Starter cover
  • Air starting motors
  • Jacket water heaters
  • 10, 20, 35 and 50 amp battery chargers

Extended Service Coverage

  • Platinum, Gold and Silver coverage

See how 3516 (50 Hz) compares against frequently compared products.

Tools And Expert Help At Every Turn

Standby power solution for mission-critical care

Edward Hospital & Health Services overcame sound and space constraints with a customized standby power solution to better support mission critical needs.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

Extended Service Coverage

Spend less time managing your equipment and more time running your business with options to protect you against unexpected repair costs.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Hire Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for hire.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Check out current offers for the 3516 (50 Hz)

View More Offers