Diesel Generator Sets D60 GC 60 kW Diesel Generator Set

Features At A Glance

Cat Generator Set Package
Cat Diesel Engine
M-Frame Alternator
GCCP 1.2 Control Panel
Cooling System
Certifications
One Safe Source
World Wide Product Support

Product Specifications for D60 GC

uom_save_thisuom_as_preferred_uom clear

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

D60 GC Standard Equipment

Certificates

  • IBC Seismic and Wind Certifications

Air Inlet System

  • Air Cleaner
  • Cartridge type air filter

Circuit Breakers

  • Breakers (100% UL rated)
  • 3-Pole 100% rated
  • Second circuit breaker box
  • Power perminal strips

Charging System

  • NFPA battery charger UL10A 120VAC

Control Panel

  • GCCP 1.2 Control panel

Exhaust System

  • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose

Fuel System

  • Standard open set fuel tank / base supplied base, formed steel with single wall integral 24-hour fuel tank

Control Panels

  • WSS1 Low coolant level shut down
  • FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected
  • NFPA110 bundle includes:
  • WCA1 Low coolant temperature alarm
  • A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
  • PBC10NU NFPA Battery Charger
  • Oil temperature guage and sender
  • PAA1 Panel mounted audible alarm
  • Ground fault relay
  • Remote E-stop button
  • Remote annunciator
  • Audible alarm
  • Volt free contacts genset run and common alarm
  • Discrete I/O module
  • Overload shutdown via breaker
  • Low coolant temperature alarm
  • Protective devices:
  • Fuel level reading
  • Low coolant level shutdown

Cooling System

  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant
  • Radiator and cooling fan with guards
  • Radiator stone guard

Generator

  • 12 leads

Governing System

  • Mechanical and electrical governing system - model dependent

Lube System

  • Oil drain line with valve
  • Lubricating oil

General

  • Engine and alternator pre-paint, Caterpillar Yellow

Starting/Charging System

  • Batteries
  • 24V battery with rack and cables

D60 GC Optional Equipment

Certificates

  • IBC Seismic and Wind Certifications

Alternator System

  • R frame auxilliary winding

Air Inlet System

  • Cartridge type air filter

Charging System

  • NFPA battery charger UL10A 120VAC

Circuit Breakers

  • Breakers (100% UL rated)
  • 3-Pole 100% rated
  • Second circuit breaker box
  • Power perminal strips

Control Panels

  • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
  • Ground fault relay
  • Remote E-stop button
  • Volt free contacts genset run and common alarm
  • Oil temperature guage and sender
  • Audible alarm
  • Remote annunciator
  • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
  • Discrete I/O module

Cooling System

  • Radiator transition flange

Enclosures

  • Sound attenuated enclosure, level 1
  • External emergency stop
  • Sound attenuated enclosure, level 2
  • Panel viewing window

Exhaust System

  • 10, 25 and 35 dBA silencer systems
  • Overhead silencer mounting kit

Fuel System

  • Emergency vent pipe
  • Tank riser
  • 5 gallon spill containment
  • 209 and 394 gallon sub-base fuel tanks
  • 5 gallon fill containment

Heating Elements

  • Battery heater
  • Jacket water heater
  • Coolant heater
  • Anti-condensation heater
  • Wiring for canopy space heater
  • Lube oil sump heater

Generators

  • Permanent magnet generator

Mounting System

  • Seismic vibration isolators

Tests

  • 4 Hour factory test
  • Generator test report
  • PGS test report @ 0.8 power factor
  • PGS test report @ 1.0 power factor

See how D60 GC compares against frequently compared products.

uom_save_thisuom_as_preferred_uom clear

Tools And Expert Help At Every Turn

SEARCH AVAILABLE STOCK IN YOUR REGION AND RESERVE 24/7

We have generator sets ready to reserve and despatch today.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

Information Library

We have an information library of product literature, white papers, customer stories, and more. Find what you’re looking for.

Learn More

Hire Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for hire.

Learn More

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Take the interactive virtual product tour to explore the great features and benefits of the D60 GC

Start D60 GC Tour

Check out current offers for the D60 GC