C2.2 (50 HZ) | 13-22 kVA Diesel Generator

Diesel Generator Sets C2.2 (50 Hz)

Request A Price Find Dealer

Key Specs

Maximum Rating
22 kVA
22 kVA
Minimum Rating
13 kVA
13 kVA
Emissions/Fuel Strategy
R96/EUIIIa Equivalent
R96/EUIIIa Equivalent

Overview

13 - 22 kVA Diesel Generator Set

Producing reliable power from 13.0 to 22.0 kVA at 50 Hz, our C2.2 diesel generator sets designed to ISO 8528-5 transient response requirements. All C2.2 generator sets are R96/EUIIIa equivalent emissions compliant.

Benefits

Over 1000 Hours Continuous Run Time

Remote Connectivity 24/7/365 Monitoring

Cat Connect option ensures your generator set is always ready to start and performing as expected

Reliability tested for over 500 Hours in Harsh & Testing environments

Product Specifications for C2.2 (50 Hz)

Maximum Rating 22 kVA 22 kVA
Minimum Rating 13 kVA 13 kVA
Emissions/Fuel Strategy R96/EUIIIa Equivalent R96/EUIIIa Equivalent
Voltage 110 to 415 Volts 110 to 415 Volts
Frequency 50 Hz 50 Hz
Speed 1500 rpm 1500 rpm
Duty Cycle Standby, Prime Standby, Prime
Engine Model Cat® C2.2, In-line 4, 4-cycle diesel Cat® C2.2, In-line 4, 4-cycle diesel
Bore 3.3 in 84 mm
Stroke 3.9 in 100 mm
Displacement 135.2 in³ 2.2 l
Compression Ratio 22.5:1 22.5:1
Aspiration Naturally Aspirated Naturally Aspirated
Fuel System Indirect Injection Indirect Injection
Governor Type Mechanical Mechanical
Length - Maximum 59.1 in 1500 mm
Width - Maximum 24.4 in 620 mm
Height - Maximum 43.9 in 1115 mm

C2.2 (50 Hz) Standard Equipment

Control Panel

  • GCCP 1.3

Air Inlet System

  • Air cleaner; light duty with disposable element

Cooling System

  • Radiator and cooling fan with guards
  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive

Fuel System

  • Standard open set fuel tank/base supplied
  • Base, formed steel with single wall integral 8-hour fuel tank

Exhaust System

  • Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

Generators and Generator Attachments

  • Voltage regulator (single phase sensing)
  • Segregated low voltage (AC/DC) wiring panel
  • Tower panel, IP22, bottom cable entry
  • IP23 Protection
  • Circuit breaker, IEC, 3 pole, mounted in tower panel
  • 12 Leads

Governing System

  • Mechanical governing system

Lube System

  • Oil drain line with valve
  • Lubricating oil

Mounting System

  • Captive linear vibration isolators between base and engine-generator
  • includes lifting provisions and termination points for coolant

Starting / Charging System

  • 12 Volt battery with rack and cables

General

  • Engine and alternator pre-paint, Caterpillar yellow

C2.2 (50 Hz) Optional Equipment

Alternator Options

  • Coastal insulation protection

Certificates

  • European upgrade to STD set for CE certificate
  • Global certification for CIS

Circuit breakers

  • Padlockable breaker device
  • 4 Pole Circuit breaker

Control Panel Options

  • Emergency stop with key
  • Volt free contacts for common alarm
  • Volt free contacts for genset running
  • GCCP 1.3
  • Battery charger

Cooling System

  • Coolant heater

Enclosures

  • Sound attenuated enclosure (GALV)
  • Single point lift for enclosure

Fuel System

  • Low fuel level alarm

Mounting Options

  • Industrial silencer removal
  • Silencer installation kit
  • Battery removal

Special Test and Inspection

  • PGS Test report @ 1.0 power factor

General

  • Packing case - compact set
  • Packing case - canopied set
  • Radiator stone guard