Electric Power 3516B (50 Hz) with Upgradeable Package 2000 - 2500 kVA Diesel Generator Set

Product Specifications for 3516B (50 Hz) with Upgradeable Package

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

3516B (50 Hz) with Upgradeable Package Standard Equipment

Air Inlet System

  • Air Cleaner; single element canister type

Control Panels

  • 1 Programmable digital outputs
  • Digital indication for
  • Frequency (Hz)
  • 4 Programmable relay outputs (Form A)
  • High coolant temperature
  • Controls:
  • Low oil pressure
  • Customer data link (Modbus RTU)
  • Load histogram feature
  • PLC functionality
  • EMCP 4.2
  • Warning / shutdown with common LED indication of shutdowns for:
  • Lamp test
  • Number of I/O varies on options selected:
  • Accessory module data link
  • Engine cycle crank
  • Over / under frequency (81 o/u)
  • Customizable screens
  • Programmable protective relaying functions:
  • kVA (per phase, average & percent)
  • Emergency stop pushbutton
  • Reverse reactive power (kVAr) (32RV)
  • Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • 6 Customer programmable digital inputs
  • Alarm acknowledge
  • Generator mounted - rear facing
  • 0 True RMS AC metering, 3-phase, +/-2% accuracy
  • DC volts
  • Generator phase sequence
  • Text alarm/event descriptions
  • kW-hr (total)
  • Engine cool-down timer
  • Over / under voltage (27/59)
  • Cat connect
  • Overspeed
  • Serial annunciator module data link
  • kW (per phase, average & percent)
  • Amps (per phase & average)
  • 1 Programmable relay outputs (Form C)
  • Coolant temperature
  • Overcurrent (50/51)
  • Volts (L-L & L-N)
  • Auto/start/stop control
  • Power Factor (per phase & average)
  • Operating hours
  • Environmental sealed front face
  • kVAr (per phase, average & percent)
  • Low coolant level
  • 24 Volt DC operation
  • kVAr-hr (total)
  • Communications:
  • Speed adjust
  • Emergency stop
  • Reverse power (kW) (32)
  • 3 Analog inputs
  • Oil pressure (psi, kPa or bar)
  • Low coolant temperature
  • Failure to start (overcrank)
  • RPM

Cooling System

  • ATAAC - 3516E Package Radiators shipped installed
  • Certified standard PGS provided

Exhaust System

  • Flanged faced outlet(s)
  • Dry exhaust manifold

Fuel System

  • Fuel priming pump
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel cooler; not included with packages without radiator

General

  • Right hand servicing
  • SAE standard rotation
  • Caterpillar yellow with high gloss black rails and radiator
  • Flywheel and flywheel housing - SAE No. 00

Generator and Attachments

  • Low voltage:
  • Winding temperature detectors
  • Busbar connections, top center mounted, top cable entry
  • NEMA standard hole pattern
  • Permanent magnet
  • 3 Phase brushless, salient pole
  • Random wound
  • 6 Leads
  • Permanent magnet
  • High voltage:
  • Form wound
  • Winding temperature detectors
  • Form wound
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Winding temperature detectors
  • Medium voltage:
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Busbar connections, right side extension box, bottom cable entry
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • NEMA standard hole pattern
  • Anti condensation Space heater
  • Internal Excitation

Governing System

  • ADEM A3

Literature

  • English

Lubrication System

  • Lubricating oil
  • Gear type lube oil pump
  • Fumes disposal
  • Integral lube oil cool
  • Oil drain lines and valve
  • Oil filter, filler and dipstick

Mounting System

  • Rubber anti-vibration mounts (shipped loose)
  • Anti-vibration mounts (shipped loose)
  • Rails - engine/generator/radiator mounting

Starting System

  • Battery and battery rack w/cables
  • 45 Amp charging alternator
  • 24 Volt electric starting motor
  • Battery disconnect switch

3516B (50 Hz) with Upgradeable Package Optional Equipment

Control System

  • EMCP4.3, EMCP 4.4
  • Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom

Air Inlet System

  • Single element filter
  • Dual element air cleaner

Engine Options

  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
  • Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Starting Motors: [ ] Standard [ ] Heavy Duty
  • Battery Charger: [ ] 10A [ ] 20A [ ] 35A
  • Starting Aids: [ ] 220V 50 Hz Jacket Water Heater
  • Muffler: [ ] Industrial Grade

Cooling System

  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Water level switch gauges
  • Standard ambient radiators
  • Optional installed radiators

Crankcase System

  • Explosion relief valves
  • No explosion relief valves
  • Ventilation system

Alternators

  • Temperature Rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Exhaust System

  • Y-Adapters
  • Flanges
  • Clean emission parts
  • Mufflers
  • Flange and exhaust expanders
  • Tier 4 clean emissions module
  • Tier 4 dosing cabinet
  • Flexible fittings
  • Elbows
  • Exhaust offset
  • Tier 4 clean emission MOD Kits

Power Termination

  • Power Termination: [ ] Bus Bar [ ] Circuit Breaker
  • Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P

Fuel System

  • Fuel Priming Pumps (Tier 4) - Manual or Electric
  • Primary Fuel Filter

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

General

  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • US aid emblem

Generators and Attachments

  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Alternator air cleaner
  • Space heater
  • Thermostate for space heater
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Differential current transformers (DCT)
  • Generator conversion

Instrumentation

  • Pyrometer and Thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • IBC vibration isolators
  • Puck style low efficiency isolators
  • Spring type vibration isolators

Power Connections

  • Neutral ground connections
  • Ground cables between generator and terminal box
  • 2700 Frame, four lead, four terminal
  • Left side power connections
  • Low voltage circuit breakers
  • Rear power connections
  • Center post busbar
  • Right side power connections

Special Tests / Reports

  • PGS test report @ 0.8 power factor
  • Generator set fuel consumption test
  • PGS test report @ 1.0 power factor
  • Standard engine test charge
  • OSHPD certification
  • Fuel consumption test
  • generator test report
  • Canadian Standards Association certification
  • IBC certification
  • Torsional vibration analysis reports

Starting and Charging

  • Air starting motors
  • Starter cover
  • 10, 20, 35 and 50 amp battery chargers
  • Air pressure regulator
  • Electric starting motors
  • 24 Volt battery set - Dry
  • Jacket water heaters
  • Engine barring device

Extended Service Coverage

  • Platinum, Gold and Silver coverage

See how 3516B (50 Hz) with Upgradeable Package compares against frequently compared products.

Tools And Expert Help At Every Turn

Dataspace trusts cat to protect their data

DataSpace has pioneered the Russian data center arena by offering reliable space, equipment, and bandwidth for leading Russian and multinational financial institutions and telecoms operating in Russia.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Hire Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for hire.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

Extended Service Coverage

Spend less time managing your equipment and more time running your business with options to protect you against unexpected repair costs.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Check out current offers for the 3516B (50 Hz) with Upgradeable Package

View More Offers