Electric Power 3516 (50 Hz) with Upgradeable Packaging 1600 - 2000 kVA Diesel Generator Set

Minimum Rating
1600 kVA
1600 kVA
Maximum Rating
2000 kVA
2000 kVA
Emissions/Fuel Strategy
Low Fuel Consumption
Low Fuel Consumption

Product Specifications for 3516 (50 Hz) with Upgradeable Packaging

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

3516 (50 Hz) with Upgradeable Packaging Standard Equipment

Air Inlet System

  • Air Cleaner; single element canister type

Control System

  • Text alarm/event descriptions
  • Environmental sealed front face
  • Speed adjust
  • Auto / start / stop control
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
  • Controls:
  • Engine cool-down timer
  • Engine cycle crank
  • 24 Volt DC operation
  • EMCP 4.2B
  • Generator set packages include Caterpillar's Voltage Regulator
  • Generator mounted - rear facing
  • Emergency stop pushbutton
  • Alarm acknowledge
  • Lamp test
  • Load histogram feature
  • PLC functionality
  • Certified standard PGS provided
  • 6 Customer programmable digital inputs
  • Number of I/O varies on options selected:
  • Digital indication for:
  • RPM
  • 3 Analog inputs
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • Customer data link (Modbus RTU)
  • Serial annunciator module data link
  • Overcurrent (50/51)
  • Accessory module data link
  • 4 programmable relay outputs (Form A)
  • Reverse Reactive Power (kVAr) (32RV)
  • ATAAC - 3516E Package Radiators shipped installed
  • 1 programmable digital outputs
  • Operating hours
  • Communications:
  • 1 programmable relay outputs (Form C)
  • Cat Connect
  • Frequency (Hz)
  • Coolant temperature
  • Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
  • Volts (L-L & L-N)
  • Power Factor (per phase & average)
  • kW (per phase, average & percent
  • kVAr (per phase, average & percent
  • kVA (per phase, average & percent)
  • Amps (per phase & average)
  • kW-hr (total)
  • kVAr-hr (total)
  • Failure to start (overcrank)
  • Overspeed
  • High coolant temperature
  • Low oil pressure
  • Emergency stop
  • Warning/shutdown with common LED indication of shutdowns for:
  • Low coolant level
  • Low coolant temperature
  • Programmable protective relaying functions
  • Reverse Power (kW) (32)
  • Over / Under voltage (27/59)
  • Generator phase sequence
  • Over / Under frequency (81 o/u)

Governing System

  • ADEM A3

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel priming pump
  • Fuel cooler; not included with packages without radiator

General

  • SAE standard rotation
  • Flywheel and flywheel housing - SAE No. 00
  • Right hand servicing
  • Caterpillar yellow with high gloss black rails and radiator

Generator and Attachments

  • NEMA standard hole pattern
  • Winding temperature detectorsle pattern
  • Internal Excitation
  • NEMA standard hole pattern
  • Busbar connections, top center mounted, top cable entry
  • 3 Phase brushless, salient pole
  • Anti Condensation Space Heater
  • Medium Voltage:
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Busbar connections, top center mounted, top cable entry
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby
  • Six lead
  • Low Voltage:
  • Form wound
  • Random wound
  • Winding temperature detectors
  • Winding temperature detectors
  • Bus bar connections, right side extension box, bottom cable entry
  • High Voltage:
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Permanent magnet
  • Permanent magnet
  • Form wound

Literature

  • English

Lubrication System

  • Gear type lube oil pump
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Integral lube oil cool
  • Lubricating oil

Mounting System

  • Anti-vibration mounts (shipped loose)
  • Rubber anti-vibration mounts (shipped loose)
  • Rails - engine / generator / radiator mounting

Starting System

  • Battery and battery rack w/cables
  • 45 Amp charging alternator
  • Battery disconnect switch
  • 24 Volt electric starting motor

3516 (50 Hz) with Upgradeable Packaging Optional Equipment

Control System

  • EMCP 4.3, EMCP 4.4
  • Local annunciator module: [ ] NFPA 110 [ ] Custom
  • Controller: [ ] EMCP 4.2 [ ] EMCP 4.3 [ ] EMCP 4.4

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Engine Options

  • Battery Charger: [ ] 10A [ ] 20A [ ] 35A
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
  • Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Starting Motors: [ ] Standard [ ] Heavy Duty
  • Starting Aids: [ ] 220V 50 Hz Jacket Water Heater
  • Muffler: [ ] Industrial Grade

Cooling System

  • Standard ambient radiators
  • Optional installed ATAAC radiators
  • Coolant
  • Standard ambient ATAAC radiators
  • Optional installed radiators
  • Water level switch gauges

Crankcase System

  • Ventilation system
  • No explosion relief valves
  • Explosion relief valves

Exhaust System

  • Y-Adapters
  • Elbows
  • Exhaust offset
  • Tier 4 clean emissions module
  • Flanges
  • Tier 4 clean emission MOD Kits
  • Mufflers
  • Flange and exhaust expanders
  • Flexible fittings
  • Clean emission parts
  • Tier 4 dosing cabinet

Alternators

  • Temperature Rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Fuel System

  • Fuel Priming Pumps (Tier 4) - Manual or electric
  • Primary Fuel Filter

General

  • The following options are based on regional and product configuration:
  • UL 2200 package
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)

Power Termination

  • Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Circuit breaker operation: [ ] Electrical
  • Power Termination: [ ] Bus Bar [ ] Circuit Breaker

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

Generators and Attachments

  • Low / medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Generator conversion
  • Thermostate for space heater
  • Space heater
  • Alternator air cleaner
  • Differential current transformers (DCT)
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Low / medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Oil level regulator
  • Prelube pumps
  • Lube oil in standard sump

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators

Power Connections

  • 2700 Frame, four lead, four terminal
  • Rear power connections
  • Right side power connections
  • Center post busbar
  • Ground cables between generator and terminal box
  • Left side power connections
  • Neutral ground connections
  • Low voltage circuit breakers

Special Tests / Reports

  • PGS test report @ 1.0 power factor
  • PGS test report @ 0.8 power factor
  • Fuel consumption test
  • Generator set fuel consumption test
  • Standard engine test charge
  • Canadian Standards Association certification
  • IBC certification
  • Torsional vibration analysis reports
  • OSHPD certification
  • Generator test report

Starting and Charging

  • Air pressure regulator
  • 24 Volt battery set - Dry
  • Air starting motors
  • Engine barring device
  • 10, 20, 35 and 50 amp battery chargers
  • Starter cover
  • Jacket water heaters
  • Electric starting motors

Extended Service Coverage

  • Platinum, Gold and Silver coverage

See how 3516 (50 Hz) with Upgradeable Packaging compares against frequently compared products.

Tools And Expert Help At Every Turn

Standby power solution for mission-critical care

Edward Hospital & Health Services overcame sound and space constraints with a customized standby power solution to better support mission critical needs.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

Hire Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for hire.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Extended Service Coverage

Spend less time managing your equipment and more time running your business with options to protect you against unexpected repair costs.

Learn More

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Check out current offers for the 3516 (50 Hz) with Upgradeable Packaging

View More Offers