Electric Power 3516 (50 Hz) with Upgradeable Package 1600 - 2000 kVA Diesel Generator Set

3516 (50 Hz) with Upgradeable Package

Features At A Glance

Cat Generator Set Package
Cat Diesel Engine
SR5 Alternator
EMCP 4 Control Panel
Cooling System
Certifications
One Safe Source
World Wide Product Support

Product Specifications for 3516 (50 Hz) with Upgradeable Package

Generator Set Specifications

Engine Specifications

Generator Set Dimensions

3516 (50 Hz) with Upgradeable Package Standard Equipment

Air Inlet System

  • Air Cleaner; single element canister type

Governing System

  • ADEM A3

Control System

  • Auto / start / stop control
  • EMCP 4.2B
  • Environmental sealed front face
  • Generator mounted - rear facing
  • Speed adjust
  • 24 Volt DC operation
  • Generator set packages include Caterpillar's Voltage Regulator
  • Text alarm/event descriptions
  • Emergency stop pushbutton
  • Engine cool-down timer
  • Engine cycle crank
  • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor
  • Controls:
  • Alarm acknowledge
  • Lamp test
  • PLC functionality
  • Load histogram feature
  • 3 Analog inputs
  • Operating hours
  • Serial annunciator module data link
  • Digital indication for:
  • 4 programmable relay outputs (Form A)
  • ATAAC - 3516E Package Radiators shipped installed
  • Communications:
  • Customer data link (Modbus RTU)
  • Reverse Reactive Power (kVAr) (32RV)
  • Accessory module data link
  • Number of I/O varies on options selected:
  • RPM
  • Overcurrent (50/51)
  • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
  • 1 programmable relay outputs (Form C)
  • 1 programmable digital outputs
  • Cat Connect
  • 6 Customer programmable digital inputs
  • Certified standard PGS provided
  • Volts (L-L & L-N)
  • Coolant temperature
  • Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)
  • Frequency (Hz)
  • kVA (per phase, average & percent)
  • Amps (per phase & average)
  • Power Factor (per phase & average)
  • kVAr (per phase, average & percent
  • kW (per phase, average & percent
  • kW-hr (total)
  • kVAr-hr (total)
  • Failure to start (overcrank)
  • Emergency stop
  • Overspeed
  • Warning/shutdown with common LED indication of shutdowns for:
  • High coolant temperature
  • Low oil pressure
  • Programmable protective relaying functions
  • Low coolant level
  • Low coolant temperature
  • Generator phase sequence
  • Over / Under frequency (81 o/u)
  • Over / Under voltage (27/59)
  • Reverse Power (kW) (32)

Exhaust System

  • Dry exhaust manifold
  • Flanged faced outlet(s)

Fuel System

  • Fuel priming pump
  • Flexible fuel lines - shipped loose
  • Secondary fuel filters
  • Fuel cooler; not included with packages without radiator

General

  • Right hand servicing
  • Flywheel and flywheel housing - SAE No. 00
  • Caterpillar yellow with high gloss black rails and radiator
  • SAE standard rotation

Generator and Attachments

  • Winding temperature detectors
  • Bus bar connections, right side extension box, bottom cable entry
  • Permanent magnet
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby
  • Busbar connections, top center mounted, top cable entry
  • Anti Condensation Space Heater
  • NEMA standard hole pattern
  • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Low Voltage:
  • Winding temperature detectors
  • Form wound
  • Medium Voltage:
  • Winding temperature detectorsle pattern
  • NEMA standard hole pattern
  • Six lead
  • Form wound
  • Internal Excitation
  • 3 Phase brushless, salient pole
  • Random wound
  • Busbar connections, top center mounted, top cable entry
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • High Voltage:

Literature

  • English

Lubrication System

  • Oil drain lines and valve
  • Lubricating oil
  • Gear type lube oil pump
  • Integral lube oil cool
  • Fumes disposal
  • Oil filter, filler and dipstick

Mounting System

  • Rails - engine / generator / radiator mounting
  • Rubber anti-vibration mounts (shipped loose)
  • Anti-vibration mounts (shipped loose)

Starting System

  • 24 Volt electric starting motor
  • 45 Amp charging alternator
  • Battery disconnect switch
  • Battery and battery rack w/cables

3516 (50 Hz) with Upgradeable Package Optional Equipment

Control System

  • Local annunciator module: [ ] NFPA 110 [ ] Custom
  • EMCP 4.3, EMCP 4.4

Air Inlet System

  • Dual element air cleaner
  • Single element filter

Cooling System

  • Water level switch gauges
  • Coolant
  • Standard ambient radiators
  • Standard ambient ATAAC radiators
  • Optional installed ATAAC radiators
  • Optional installed radiators

Engine Options

  • Starting Aids: [ ] 220V 50 Hz Jacket Water Heater
  • Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners
  • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)
  • Starting Motors: [ ] Standard [ ] Heavy Duty
  • Muffler: [ ] Industrial Grade

Crankcase System

  • Explosion relief valves
  • Ventilation system
  • No explosion relief valves

Alternators

  • Temperature Rise (over 40°C ambient): [ ] 150°C [ ] 125°C [ ] 105°C [ ] 80°C

Exhaust System

  • Y-Adapters
  • Exhaust offset
  • Tier 4 dosing cabinet
  • Flexible fittings
  • Elbows
  • Clean emission parts
  • Tier 4 clean emissions module
  • Flanges
  • Tier 4 clean emission MOD Kits
  • Mufflers
  • Flange and exhaust expanders

Fuel System

  • Fuel Priming Pumps (Tier 4) - Manual or electric
  • Primary Fuel Filter

General

  • UL 2200 package
  • US aid emblem
  • Special paint (Colors other than Caterpillar yellow or high performance paints)
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • The following options are based on regional and product configuration:

Power Termination

  • Circuit breaker operation: [ ] Electrical
  • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P
  • Power Termination: [ ] Busbar [ ] Circuit Breaker
  • Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

Generators and Attachments

  • Low / medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
  • Low / medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
  • Space heater
  • Differential current transformers (DCT)
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
  • Generator conversion
  • Differntial current transformers (DCT) 8.7 kV and 15 kV classes
  • Thermostate for space heater
  • Alternator air cleaner
  • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
  • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

Extended Service Contract (ESC)

  • Extended Service Contract (ESC): [ ] 2 Year [ ] 3 Year [ ] 5 Year

Instrumentation

  • Pyrometer and thermocouples

Lubrication System

  • Lube oil in standard sump
  • Prelube pumps
  • Oil level regulator

Mounting System

  • Puck style low efficiency isolators
  • Spring type vibration isolators
  • IBC vibration isolators

Power Connections

  • Right side power connections
  • Ground cables between generator and terminal box
  • 2700 Frame, four lead, four terminal
  • Neutral ground connections
  • Rear power connections
  • Low voltage circuit breakers
  • Center post busbar
  • Left side power connections

Special Tests / Reports

  • PGS test report @ 0.8 power factor
  • PGS test report @ 1.0 power factor
  • Canadian Standards Association certification
  • Standard engine test charge
  • IBC certification
  • Generator set fuel consumption test
  • OSHPD certification
  • Generator test report
  • Torsional vibration analysis reports
  • Fuel consumption test

Starting and Charging

  • 10, 20, 35 and 50 amp battery chargers
  • 24 Volt battery set - Dry
  • Electric starting motors
  • Air starting motors
  • Starter cover
  • Engine barring device
  • Air pressure regulator
  • Jacket water heaters

Extended Service Coverage

  • Platinum, Gold and Silver coverage

See how 3516 (50 Hz) with Upgradeable Package compares against frequently compared products.

Tools And Expert Help At Every Turn

Customer Value Agreements

Every piece of Cat equipment is designed and built to provide maximum productivity and operating economy throughout its working life. Your Cat dealer can help you maintain that built-in value through a Customer Value Agreement (CVA).

Learn More

Rent Similar Size

View our full lineup of construction equipment rental products featuring a wide range of portable generator rental options as well as mobile generator sets for rent.

Learn More

Standby power solution for mission-critical care

Edward Hospital & Health Services overcame sound and space constraints with a customized standby power solution to better support mission critical needs.

Learn More

Technical Resources

Explore valuable resources for generator sizing, specification, and training materials.

Learn More

SpecSizer

Calculate what generator size you need by using our commercial and industrial generator sizing calculator, SpecSizer.

Learn More

Cat Connect: Get More from Every Asset

Now there's an easier way to track and manage your equipment anytime, anywhere.

Learn More

Extended Service Coverage

Spend less time managing your equipment and more time running your business with options to protect you against unexpected repair costs.

Learn More

Custom Power Solutions

There are no standard power solutions. Cat experts work with you to design a system to meet your individual power needs.

Learn More

Product Brochures and More Are Ready to Download!

Full specifications, product brochures and more. Sign up below for additional information. Or for instant access, you can skip this form.


Check out current offers for the 3516 (50 Hz) with Upgradeable Package

View More Offers